1. Intended Application for Quest Dehumidifer
The Quest 335 Dehumidifer is designed to operate in temperatures between 56° and 95°F.
In order to efciently control humidity levels, the area in which the dehumidifer is to be operated must be free of water
intrusion or excessive fresh (outside) air infltration. Before installing the Quest 335 Dehumidifer, water intrusion and air
infltration problems should be addressed or noted in calculations.
2. Registrations
The Quest 335 Dehumidifer units conform to unifed standard UL 60335-2-40, CSA C22,2#60335-2-40.
US Patents: D570,988 / 8,069,681 / 9,052,132
3. Specifcations @ 80°F/60% RH
Unit:
4042500 Quest 335
Blower:
(Tested with duct collars on)
1000 CFM @ 0.0” WG
1000 CFM @ 0.2” WG
1000 CFM @ 0.4” WG
Power (Watts):
1565
Supply voltage:
208V and 230V -
1 Phase - 60 Hz.
Current Draw (Amps):
6.9A @ 230V
7.9A @ 208V
Energy Factor: (L/kWh)
4.4
Operating Temp:
56°F - 95°F
Water Removal (Pints/Day):
Efciency (Pints/kWh):
335
9.3
Air Filter (MERV-11 Nominal):
Size: 22” x 20” x 2”
Power Cord:
10’ 14/3 SJTW
NEMA 6-15P
Drain Connection:
3/4” Threaded NPT
Refrigerant Type:
R410A
Refrigerant Amount:
4lb. 12oz.
Dimensions:
Unit
Shipping
Width:
32.88”
36”
Height:
24.38”
30”
Length:
23.5”
28”
Weight:
215 lbs
255 lbs
4