Thermann Installer's Manual
Gas Continuous Flow Water Heaters
Connecting the Quick Connect Cord to the two units.
1. Turn off the power.
2. Remove the front cover of the heater (4 screws).
3. Pass the Quick Connect Cord through the wiring throughway and into the unit.
4. Plug the connector on the Quick Connect Cord to the receptacle inside the unit.
5. Attach the ground wire of the Quick Connect Cord to the terminal block fixing plate.
(If the ground wire is not attached, electrical noise may cause problems).
6. Secure the Quick Connect Cord with a clamp.
7. Replace the front cover.
Caution
For Quick Connect Multi System Installation use part No.CF-0706891 only. (sold separately).
Quick Connect
Cord
"Quick Connect Cord" tag
A
B
1.Red
2.Black
3.White
4.Green
5.Blue
6.Blue
1.Red
2.Black
3.White
4.Green
5.Blue
6.Blue
1.Red
2.Black
3.White
4.Green
5.Blue
6.Blue
1.White
2.Green
3.Red
4.Black
5.Blue
6.Blue
The wire coloring on the Quick Connect Cord will
not be the same as the wire coloring of the
connection plug inside the unit.
* The remote controller can be connected to either
unit A or B. Do not connect a remote controller to
both units.
* Disconnect the remote controller from either unit
A or B prior to installing the Quick Connect Cord.
Connecting Quick Connect Cord
Wiring Throughway
Wiring Throughway
Coupling Cord
Coupling Cord
Clamp
Clamp
Ground wire Connector
(Use one of the vacant holes)
Ground wire Connector
Connector
Connector
TH32ECR6 series
TH28ENR6 series
Wiring Throughway
Coupling Cord
Clamp
Ground wire Connector
(Use one of the vacant holes)
Connector
TH50ECR6 series
32
Содержание TH28ENR6L
Страница 9: ...Component Details Example TH50ECR6 series model shown for illustration only Ex TH50ECR6 9 ...
Страница 11: ...TH28ENR6 series model shown for illustration only Ex TH28ENR6 11 ...
Страница 49: ...49 Memo ...
Страница 50: ...Thermann Installer s Manual Gas Continuous Flow Water Heaters 50 Memo ...
Страница 51: ...51 Memo ...
Страница 52: ......