950-0211revA - 8 - March 7, 2014
Installation (C
ONT’D)
Step 5
Prepare Unit Line Set Connections
Rotate refrigerant line stubs set gently through 90° (if mounting on an outside wall). For other line set
configurations align the stubs as required.
Tips:
Use Duct tape to tape the condensate hose (make sure it
is below the line set stubs). This makes it easier to guide them
through the hole drilled in the wall.
Feed the 16 AWG interconnect wiring between indoor
and outdoor (maximum # of wires required is 4) through the
unit electrical connection (if required by local codes an
electrical connector can be attached to the rear of the unit).
Tape the loose wire to the line set stubs.
These two tips save time and prevent damage to the
stubs when mounting the Indoor unit.
Note:
Condensate hose is taped below line set stubs. Wrap Duct
tape to the end of the condensate hose for easier
installation.
Pipe
D ra i n h o se
Vi n yl ta p e
Wra p w i th
vi n yl ta p e
C o n n e cti n g ca b l e
Suction Line
Liquid Line
Condensation Drain
Control cable