![Thermal Dynamics DRAG-GUN 38 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/thermal-dynamics/drag-gun-38/drag-gun-38_instruction-manual_1103258032.webp)
SECTION 5: SERVICE
26
Manual 0-2729
No
Yes
AC and Gas Indicators are ON
Temperature Indicator Either
ON or Blinks Once
When Torch Switch (TS) is Pressed
Troubleshooting Chart #3: Temperature Indicator Checks
Replace Power Supply
Assembly
Duty Cycle
Exceeded?
No
Yes
Allow Power Supply
To Cool
Temperature
Indicator ON?
Yes
No
Use Proper
Operating Procedures
Temperature
Indicator Still
ON?
Yes
No
Fan
Operating?
Yes
No
Temp Indicator
ON Steady
When TS is
Pressed
(blinks once)
Disconnect Pilot Wire
and retry torch switch
TEMP LED
Blinks
Yes
No
Check Torch & Leads
per Section 5.10 A & B
Replace
Power Supply