Manual 0-4678
3-1
Installation
SECTION 3:
INSTALLATION
3.01 Site Selection
• Place in a clean and dry area.
• Provide adequate ventilation and fresh air sup-
ply.
• Ideal ambient temperature should not exceed
40°C / 104°F. Temperatures exceeding that may
diminish cutting capacity or quality.
• The cutting machine must be placed on an even,
firm surface so that it stands firmly.
3.02 Electrical Input Connections
• Input voltage is 230V ± 10%, 50/60 Hz single
phase.
CAUTION
Check your power source for correct voltage be-
fore plugging in or connecting the unit. The
primary power source, fuse, and any extension
cords used must conform to local electrical code
and the recommended circuit protection and wir-
ing requirements as specified in Section 2.0.
3.03 Compressed Air Connection
• An air compressor is required and should be con-
nected to rear panel of power source by air hose.
• Air pressure should be 75 psi (5.2 bar) (.52MPa)
and air should be dry and clean.
• Air flow should be 400 scfh / 6.6 scfm (188.7 lpm)
minimum.
Connect
Air Here
Input
Power
Art # A-04485
DANGER
Do not cut in humid or wet surroundings.
• Before you maintain or replace torch parts, wait
for the post flow air cycle (approximately 10 sec-
onds), to stop, then turn the machine off.
• Always use original manufacturers parts. The use
of aftermarket parts could result in shorter parts
life and in unsatisfactory cutting results. Any war-
ranty claims would be waived.
NOTE
Repairs must be done by skilled and qualified
personnel only.
Содержание CUTSKILL C-35A
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 12: ...GENERAL INFORMATION 1 6 Manual No 0 4678 This Page Left Blank...
Страница 16: ...Installation 3 2 Manual 0 4678 This Page Left Blank...
Страница 20: ...Operation 4 4 Manual 0 4678 This Page Left Blank...
Страница 24: ...SERVICE 5 4 Manual 0 4678 This Page Left Blank...
Страница 29: ...Manual 0 4678 A 5 APPENDIX 5 6 3 4 2 7 7 A 07060 1 8...
Страница 34: ...APPENDIX A 10 Manual 0 4678 This Page Left Blank...