POWER SOURCE ERROR CODE
10 – 1
POWER SOURCE ERROR CODE
Description
Possible Cause
Remedy
Remarks
1. E01 error code displayed
Temperature sensor TH1
(protects IGBTs) is
greater than 80
°
C for
about 1 second.
A. The Welding Power
Source's duty cycle has
been exceeded.
B. Fan ceases to operate.
C. Air flow is restricted by
vents being blocked.
A. Let Power Source cool
down then keep within its
duty cycle.
B. Have an Accredited
Thermal Arc Service
Agent investigate.
C. Unblock vents then let
Power Source cool down.
Weld current ceases.
Buzzer sounds constantly.
Fan operates at max speed.
E01 resets when TH1
decreases to 70
°
C for about
30 seconds.
2. E02 error code displayed
Temperature sensor TH2
(protects secondary
diodes) is greater than
80
°
C for about 1 second.
A. The Welding Power
Source's duty cycle has
been exceeded.
B. Fan ceases to operate.
C. Air flow is restricted by
vents being blocked.
A. Let Power Source cool
down then keep within its
duty cycle.
B. Have an Accredited
Thermal Arc Service
Agent investigate
C. Unblock vents then let
Power Source cool down.
Weld current ceases.
Buzzer sounds constantly.
Fan operates at max speed.
E02 resets when TH2
decreases to 70
°
C for about
30 seconds.
3. E03 error code displayed
Transformer current too
high.
A. Transformer current is
too high because welding
arc is too long.
B. Mains supply voltage is
more than 10% below
nominal voltage .
A. Reduce length of welding
arc.
B. Have an Accredited
Thermal Arc Service
Agent or a qualified
electrician check for low
Mains voltage.
Weld current ceases.
Buzzer sounds constantly.
Switch machine off then on
to reset E03 error.
4. E04 error code displayed
Output voltage exceeds
the secondary voltage
specification.
TIG torch cable and/or work
lead are too long or leads
are coiled.
Reduce the length of the
TIG torch cable and/or work
lead or un-coiled leads.
Weld current ceases.
Buzzer sounds constantly.
Switch machine off then on
to reset E04 error.
5. E11 error code displayed
Over Primary supply
(input) voltage at primary
capacitors is exceeded
for one second.
Primary supply voltage is
greater than the nominal
voltage plus 10%.
Have an Accredited Thermal
Arc Service Agent or a
qualified electrician check
the Primary voltage.
Weld current ceases.
Buzzer sounds constantly.
Error code E11
automatically will reset when
the voltage reduces.
6. E14 error code displayed
Under mains supply
(input) voltage warning
primary capacitors is
reduced for one second.
Mains supply voltage is less
than the nominal operating
voltage less 10%.
Have an Accredited Thermal
Arc Service Agent or a
qualified electrician check
the Mains voltage.
Weld current available.
Buzzer sounds
intermittently./Error code
E14 automatically will reset
when the voltage increases.
7. E12 error code displayed
Under mains supply
(input) voltage primary
capacitors is reduced for
one second.
Mains supply voltage is
down to a dangerously low
level.
A. Have an Accredited
Thermal Arc Service
Agent or a qualified
electrician check the
Mains voltage.
B. Have an Accredited
Thermal Arc Service
Agent or a qualified
electrician check the
primary cable and fuses.
Weld current ceases.
Buzzer sounds constantly.
Error code E12
automatically will reset when
the voltage increases.
8. E81 error code displayed
Wrong Primary supply
(input) voltage
connected.
When 3 phase machine is
first turned on with the
wrong Primary supply (input)
voltage connected.
Have an Accredited Thermal
Arc Service Agent or a
qualified electrician check
the Mains voltage.
No weld current is available.
Buzzer sounds constantly.
Switch machine off.
Содержание ARCMASTER 300 AC/DC
Страница 2: ......
Страница 31: ...300ACDC 5 SET UP FOR SMAW STICK AND GTAW TIG 5 2 PAGE LEFT INTENTIONALLY BLANK ...
Страница 35: ...300ACDC 7 ROUTINE MAINTENANCE 7 2 PAGE LEFT INTENTIONALLY BLANK ...
Страница 41: ...300ACDC 8 BASIC TROUBLESHOOTING 8 6 PAGE LEFT INTENTIONALLY BLANK ...
Страница 109: ...THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 113: ......