300ACDC
10
POWER SOURCE ERROR CODE
10 – 2
Table 10-1: Power Source Error Codes
9. E82 error code displayed
Rated voltage selection
circuit abnormality.
The Primary supply (input)
voltage fluctuates and is not
stable.
Have an Accredited Thermal
Arc Service Agent or a
qualified electrician check
the Mains voltage.
No weld current is available.
Buzzer sounds constantly.
Switch machine off then on
to reset E82 error.
10.E83 error code displayed
CPU checks mains
supply (input) voltage
when the on/off switch on
rear panel of machine is
turned ON.
The Primary supply (input)
voltage fluctuates and is not
stable.
Have an Accredited Thermal
Arc Service Agent check
connector plug on input PCB
and the Mains voltage.
No weld current is available.
Buzzer sounds constantly.
Switch machine off then on
to reset E83 error.
11.E85 error code displayed
Pre-charge abnormality.
Due to malfunction inside
the Welding Power Source,
primary capacitors are not
charging correctly.
Have an Accredited Thermal
Arc Service Agent service
the machine.
No weld current is available.
Buzzer sounds constantly.
Switch machine off then on
to reset E85 error.
12.E93 error code displayed
Memory chip (EEPROM)
on control PCB can not
read/write weld
parameters.
Memory chip (EEPROM)
error.
Have an Accredited Thermal
Arc Service Agent check the
control PCB.
Weld current ceases.
Buzzer sounds constantly.
Switch machine off.
13.E94 error code displayed
Temperature sensor TH1
for IGBTs or sensor TH2
for secondary diodes are
open circuit.
The Welding Power
Source's temperature
sensors have malfunctioned.
Have an Accredited Thermal
Arc Service Agent check or
replace the temperature
sensors.
Weld current ceases.
Buzzer sounds constantly.
Switch machine off.
14.E99 error code displayed
Mains supply (input)
voltage has been turned
off but control circuit has
power from the primary
capacitors.
A. Main on/off switch on
machine has been turned
off
B. Mains supply (input)
voltage has been turned
off.
A. Turn on/off switch on.
B. Have an Accredited
Thermal Arc Service
Agent or a qualified
electrician check the
Mains voltage and fuses.
Weld current ceases.
Buzzer sounds constantly.
Must switch machine off
then on to reset E99 error.
Description
Possible Cause
Remedy
Remarks
Содержание ARCMASTER 300 AC/DC
Страница 2: ......
Страница 31: ...300ACDC 5 SET UP FOR SMAW STICK AND GTAW TIG 5 2 PAGE LEFT INTENTIONALLY BLANK ...
Страница 35: ...300ACDC 7 ROUTINE MAINTENANCE 7 2 PAGE LEFT INTENTIONALLY BLANK ...
Страница 41: ...300ACDC 8 BASIC TROUBLESHOOTING 8 6 PAGE LEFT INTENTIONALLY BLANK ...
Страница 109: ...THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 113: ......