300ACDC
11
ADVANCED TROUBLESHOOTING
11 – 3
6) Remove protection cover sheet by removing
the plastic tabs.
Figure 11-6: Remove PCB cover
NOTE
When you re-assemble the parts, conduct the
above process backwards.
2
Verification and Remedy to
the Indicated Error Codes
NOTE
The capacitors inside the power supply will slowly
discharged after you turn off the switch of the
power supply or the switch at the breaker box (dis-
tribution panel). Wait at least 5 minutes for the dis-
charge to complete and then remove the cases to
continue your inspection and repair (or mainte-
nance) inside the power supply. As for the removal
and installation of the case, refer to section 11.1.1.
NOTE
During the "
Verification/Remedy
" procedures
below, follow the alphabetical sequence (a, b, c...)
and proceed with your verification and confirma-
tion.
NOTE
After you confirm and replace all spare parts and
components, confirm that there are no damaged
harnesses or connectors, uninstalled or loose
screws.
2.1 E01 "Over-Temperature at
the primary side"
Cause
Occurs when an over-temperature condition of the
primary IGBT is detected.
Verification/Remedy
a) Unit may be in thermal shutdown mode.
Review the rated duty cycle of the unit per
section 3.8. Exceeding the duty cycle can
damage the unit and void the warranty. Refer
also to section 1.6 for additional information.
b) Verify the ventilating condition.
Maintain a clear and unobstructed distance
of more than 30cm in the front and more that
50cm in the rear of the unit for ventilation pur-
poses.
Verify and maintain clean, dust free, front and
rear airflow paths. Cleaning and removing
dust from the front and rear panels once
every six months in a normal working envi-
ronment is recommended. Extremely dusty
environments will require more frequent
cleanings.
c) Verify the operation of the cooling fan, FAN1,
and replace it if necessary.
Verify the condition of FAN1. Verify that
there are no broken or cracked fan blades
and that FAN1 is not producing any abnormal
sounds.
If broken or cracked FAN1 blades, or abnor-
mal sounds are emanating from FAN1,
replace FAN1.
Verify the operation of the cooling fan and
replace it if the condition of FAN1 is inactive.
Follow the instruction in section.
Refer to section 12.3.24 for the replacement
of FAN1.
Refer to section 11.5.3 for additional FAN1
tests.
d) Replace PCB6 (WK-5549).
Refer to section 12.3.6 for the replacement of
PCB6.
Содержание ARCMASTER 300 AC/DC
Страница 2: ......
Страница 31: ...300ACDC 5 SET UP FOR SMAW STICK AND GTAW TIG 5 2 PAGE LEFT INTENTIONALLY BLANK ...
Страница 35: ...300ACDC 7 ROUTINE MAINTENANCE 7 2 PAGE LEFT INTENTIONALLY BLANK ...
Страница 41: ...300ACDC 8 BASIC TROUBLESHOOTING 8 6 PAGE LEFT INTENTIONALLY BLANK ...
Страница 109: ...THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 113: ......