Weld Parameters for ARC MASTER 300ACDC
Table 4-4: Weld Parameters for ARC MASTER 300ACDC
Table 4-5: PULSE FREQ. Range and Incremental Units
Weld Mode
Weld Parameter
Parameter
Range
Factory Setting
Incremental Unit
STICK
HF TIG
LIFT TIG
PRE-FLOW
0.0 to 1.0 sec
0 sec
0.1 sec
No
Yes
Yes
HOT START
0 to 70A
20A
1A
Yes
Yes
No
INITIAL CUR.
5 to 300A
30A
1A
No
Yes
Yes
UP SLOPE
0 to 15 sec
1 sec
0.1 sec
No
Yes
Yes
PULSE PEAK CUR.
5 to 300A
120A
1A
No
Yes
Yes
PULSE BASE CUR.
5 to 300A
80A
1A
No
Yes
Yes
WELD CUR.
5 to 300A
80A
1A
Yes
Yes
Yes
SPOT TIME
0.5 to 5.0 sec
2 sec
0.1 sec
No
Yes
Yes
PULSE WIDTH
15 to 80%
50%
1%
No
Yes
Yes
PULSE FREQ.
0.5 to 500Hz
100.0Hz
See Table
Table 4-5
No
Yes
Yes
AC FREQUENCY
15 to 150Hz
60Hz
1Hz
Yes
Yes
Yes
WAVE BALANCE
10 to 65%
50%
1%
Yes
Yes
Yes
DOWN SLOPE
0 to 25 sec
3 sec
0.1 sec
No
Yes
Yes
CRATER CUR.
5 to300A
30A
1A
No
Yes
Yes
POST-FLOW
0.0 to 60 sec
10 sec
0.1 sec
No
Yes
Yes
PULSE FREQ. Range
Incremental Unit
0.5 to 20Hz
0.1Hz
20 to 100Hz
1Hz
100 to 500Hz
5Hz
Содержание ARCMASTER 300 AC/DC
Страница 2: ......
Страница 31: ...300ACDC 5 SET UP FOR SMAW STICK AND GTAW TIG 5 2 PAGE LEFT INTENTIONALLY BLANK ...
Страница 35: ...300ACDC 7 ROUTINE MAINTENANCE 7 2 PAGE LEFT INTENTIONALLY BLANK ...
Страница 41: ...300ACDC 8 BASIC TROUBLESHOOTING 8 6 PAGE LEFT INTENTIONALLY BLANK ...
Страница 109: ...THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 113: ......