INSTALLATION/SETUP
FABRICATOR 211i
Manual 0-5157
3-3 INSTALLATION/SETUP
WARNING
An electrical shock or fire hazard is probable if the following electrical service guide recommendations are
not followed. These recommendations are for a dedicated branch circuit sized for the rated output and duty
cycle of the welding Power Source.
50 / 60 Hz Single Phase Supply
Supply Voltage
208/230V AC
115V AC
Input Current at Maximum Output
32 Amps
30 Amps
Maximum Recommended Fuse* or Circuit Breaker Rating
* Time Delay Fuse, UL class RK5. Refer to UL248
50 Amps
50 Amps
30 Amps
30 Amps
Maximum Recommended Fuse^ or Circuit Breaker Rating
^Normal Operating , UL class K5. Refer to UL248
Minimum Recommended Cord Size
12 AWG
12 AWG
Maximum Recommended Extension Cord Length
50 ft
25 ft
Minimum Recommended Grounding Conductor Size
12 AWG
12AWG
Table 3-1: Electrical Service Guide
CAUTION
The time-delay fuses or circuit breaker of an individual branch circuit may have nuisance tripping when
welding with this product due to the amperage rating of the time-delay fuses or circuit breaker.
Art# A-11240
Primary Power Cable
115
115
V,
V,
20A, 1Ø
15A, 1Ø
208/230V, 50A, 1Ø
The Adapter enable
connection to all these
power outlets
115 VAC Adapter
Figure 3-2: Electrical Input Connections
Содержание 211i
Страница 6: ......
Страница 32: ...FABRICATOR 211i INTRODUCTION INTRODUCTION 2 8 Manual 0 5157...
Страница 82: ...FABRICATOR 211i BASIC WELDING BASIC WELDING 4 22 Manual 0 5157...