FABRICATOR 211i
INTRODUCTION
INTRODUCTION
2-4
Manual 0-5157
2.09 Specifications
Description
Fabricator 211i Multi Process 3 in 1 Welder
Power Source Part No.
W1004200
Power Source Dimensions
H17.12" x W10.47" x D 24.29" (435mm x 266mm x D617mm)
Power Source Mass
57.3lb (26kg)
Cooling
Fan Cooled
Welder Type
Multi Process Welding System
Applicable Standard
CSA E60974-1-00 / UL60974-1 / IEC 60974-1
Number of Phases
Single Phase
Nominal Supply Voltage
208/230 VAC ± 10%
115VAC± 10%
Nominal Supply Frequency
50/60Hz
50/60HZ
Welding Current Range
MIG Mode
STICK Mode
TIG Mode
10-210 Amps
10-200 Amps
10-200 Amps
10-140 Amps
10-110 Amps
10-150 Amps
Wirefeed Speed Range
100 - 600 IPM
100 - 400 IPM
MIG Welding Voltage Range
14.5 - 24.5V DC
14.5 - 19V DC
Nominal OCV
70V DC
Effective Input Current (I
1eff
)
for MIG (GMAW/FCAW)
for STICK (SMAW)
for LIFT TIG (GTAW)
14.4A/11.2A
16.8A/15.8A
11.7A/11.5A
15.5A
17.8A
17.4A
Maximum Input Current (I
1max
)
for MIG (GMAW/FCAW)
for STICK (SMAW)
for LIFT TIG (GTAW)
32.2A/25.0A
33.6A/31.6A
23.3A/22.9A
24.5A
30.1A
29.4A
Single Phase Generator Requirement
7.5 kVA
*3.7 kVA
MIG (GMAW/FCAW) Welding Output, 104°F, 10 min.
210A @ 20%,24.5V
122A @ 60%, 20.1V
95A @ 100%, 18.8V
110A @ 45%,19.5V
99A @ 60%, 19.0V
77A @ 100%, 17.9V
STICK (SMAW) Welding Output,1040°F, 10 min.
200A @ 25%,28.0V
130A @ 60%, 25.2V
101A @ 100%, 24.0V
110A @ 35%,24.4V
90A @ 60%, 23.6V
70A @ 100%, 22.8V
TIG (GTAW) Welding Output, 104°F, 10 min.
200A @ 25%,18.0V
130A @ 60%, 15.2V
101A @ 100%, 14.0V
150A @ 35%,16.0V
115A @ 60%, 14.6V
90A @ 100%, 13.6V
Open Circuit Voltage
70 V
Protection Class
IP23S
Table 2-1: Fabricator 211i Specifications
Note 1: The Effective Input Current should be used for the determination of cable size & supply requirements.
Note 2: Motor start fuses or thermal circuit breakers are recommended for this application. Check local require-
ments for your situation in this regard.
Note 3: Generator Requirements at the Maximum Output Duty Cycle.
* Some 115 VAC, 15 amp/20 amps electrical outlets fitted with GFCI (Ground Fault Circuit Interrupt) protection
amy nuisance trip with this equipment due to worn or out of tolerance components in the GFCI. In such cases
have the 115 VAC, 15 amp/20 amp FGCI electrical outlet replaced by a qualified electrical trades person.
Содержание 211i
Страница 6: ......
Страница 32: ...FABRICATOR 211i INTRODUCTION INTRODUCTION 2 8 Manual 0 5157...
Страница 82: ...FABRICATOR 211i BASIC WELDING BASIC WELDING 4 22 Manual 0 5157...
Страница 92: ...FABRICATOR 211i REPLACEMENT PARTS REPLACEMENT PARTS 6 4 Manual 0 5157...