THERMAL ARC 161STL, 201TS
SAFETY AND INSTALLATION
Safety and Installation
3-8
Manual 0-5148
3.07 Electromagnetic Compatibility
WARNING
Extra precautions for Electromagnetic
Compatibility may be required when this
Welding Power Source is used in a domestic
situation.
A. Installation and Use - Users Responsibility
The user is responsible for installing and using the welding
equipment according to the manufacturer’s instructions.
If electromagnetic disturbances are detected then it shall
be the responsibility of the user of the welding equipment
to resolve the situation with the technical assistance of
the manufacturer. In some cases this remedial action
may be as simple as earthing the welding circuit, see
NOTE below. In other cases it could involve constructing
an electromagnetic screen enclosing the Welding Power
Source and the work, complete with associated input
filters. In all cases, electromagnetic disturbances shall be
reduced to the point where they are no longer Trouble-
some.
B. Assessment of Area
Before installing welding equipment, the user shall make
an assessment of potential electromagnetic problems in
the surrounding area. The following shall be taken into
account.
1. Other supply cables, control cables, signaling and
telephone cables; above, below and adjacent to the
welding equipment.
2. Radio and television transmitters and receivers.
3. Computer and other control equipment.
4. Safety critical equipment, e.g. guarding of industrial
equipment.
5. The health of people around, e.g. the use of pace-
makers and hearing aids.
6. Equipment used for calibration and measurement.
7. The time of day that welding or other activities are to
be carried out.
8. The immunity of other equipment in the environment:
the user shall ensure that other equipment being used
in the environment is compatible: this may require
additional protection measures.
The size of the surrounding area to be considered will
depend on the structure of the building and other activities
that are taking place. The surrounding area may extend
beyond the boundaries of the premises.
C. Methods of Reducing Electromagnetic Emissions
1. Mains Supply
Welding equipment should be connected to the
mains supply according to the manufacturer’s
recommendations. If interference occurs, it may be
necessary to take additional precautions such as
filtering of the mains supply. Consideration should
be given to shielding the supply cable of permanently
installed welding equipment in metallic conduit or
equivalent. Shielding should be electrically continuous
throughout its length. The shielding should be
connected to the Welding Power Source so that good
electrical contact is maintained between the conduit
and the Welding Power Source enclosure.
2. Maintenance of Welding Equipment
The welding equipment should be routinely maintained
according to the manufacturer’s recommendations. All
access and service doors and covers should be closed
and properly fastened when the welding equipment
is in operation. The welding equipment should not
be modified in any way except for those changes
and adjustments covered in the manufacturer’s
instructions. In particular, the spark gaps of arc
striking and stabilizing devices should be adjusted
and maintained according to the manufacturer’s
recommendation
3. Welding Cables
The welding cables should be kept as short as possible
and should be positioned close together, running at or
close to the floor level.
4. Equipotential Bonding
Bonding of all metallic components in the welding
installation and adjacent to it should be considered.
However, metallic components bonded to the work
piece will increase the risk that the operator could
receive a shock by touching the metallic components
and the electrode at the same time. The operator
should be insulated from all such bonded metallic
components.
Содержание 161 STL
Страница 6: ......
Страница 16: ...THERMAL ARC 161STL 201ts INTRODUCTION Introduction 2 2 Manual 0 5148 Notes...
Страница 28: ...THERMAL ARC 161STL 201ts SAFETY AND INSTALLATION Safety and Installation 3 12 Manual 0 5148 Notes...
Страница 42: ...THERMAL ARC 161Stl 201ts THEORY OF OPERATION Theory of Operation 5 2 Manual 0 5148 Notes...
Страница 56: ...THERMAL ARC 161Stl 201TS troubleshooting Troubleshooting 6 14 Manual 0 5148 6 11 161STL Connector Diagram...
Страница 72: ...THERMAL ARC 161Stl 201ts disassembly procedure Disassembly Procedure 7 14 Manual 0 5148 Notes...
Страница 75: ...ASSEMBLY PROCEDURE THERMAL ARC 161stl 201TS Manual 0 5148 8 3 Assembly Procedures 6 7 Art A 10183 8 Art A 09883...
Страница 81: ...ASSEMBLY PROCEDURE THERMAL ARC 161stl 201TS Manual 0 5148 8 9 Assembly Procedures 11 Art A 10190...
Страница 83: ...ASSEMBLY PROCEDURE THERMAL ARC 161stl 201TS Manual 0 5148 8 11 Assembly Procedures 2 Art A 10192...
Страница 84: ...THERMAL ARC 161Stl 201ts ASSEMBLY PROCEDURES Assembly Procedures 8 12 Manual 0 5148 Notes...
Страница 90: ...THERMAL ARC 161Stl 201TS replacement parts Replacement Parts 9 6 Manual 0 5148 Notes...
Страница 92: ...THERMAL ARC 161Stl 201TS accessories Accessories 10 2 Manual 0 5148 Notes...
Страница 95: ......