Prepare holes at fastener locations as identified below:
•
For walls, wall studs, or floors composed of solid wood
or metal, drill 1/8” (3mm) pilot holes.
•
For walls or floors composed of drywall, sheet-rock or
other soft materials, drill 3/16” (5mm) holes to a
minimum depth of 1¾” (45mm), then tap plastic
anchors into each of the holes using a hammer.
•
For walls or floors composed of concrete or concrete
block, drill 3/16” (5mm) holes to a minimum depth of
1¾” (45mm), then tap concrete anchors into each of
the holes using a hammer.
•
For walls or floors having ceramic tile covering, drill 3/
16” (5mm) holes through the tile only, then drill into the
material behind the tile as indicated immediately
above.
Mounting Anti-Tip Bracket
The floor mounted bracket shall be installed as follows:
1.
Place bracket on floor in position shown in
.
•
30” and 36” bracket may be used in either corner of
the installation area.
2.
Secure to floor and wall stud using the (4) 1½” (38mm)
Phillips head screws provided.
3.
Later, when the unit is installed, the adjustable leg will
slide under the bracket, as shown in
4.
If the range is moved to a new location, the Anti-Tip
Device must be removed and reinstalled.
Figure 7: Anti-Tip Bracket
Range leg will
slide into bracket
slot after installation.
Figure 8: Placement of Anti-Tip Bracket (Top View)
Wall Line
Fl
oo
r
Left
Cabinet
Right
Cabinet
X
From Edge
of Range
X
typical—
either side
Front edge
of right
cabinet
X
= 4½” (114mm) [for 30” range]
X
= 6¾” (171mm) [for 36” range]
X
= 4½” (116mm) [for 48” range, right side]