Installation, Operation and Maintenance Instructions

4

www.QuestClimate.com

[email protected]

1.  Intended Application for Quest Dual

The Quest Dual Dehumidifier is designed to operate in temperatures between 56° and 95°F. 
In order to efficiently control humidity levels, the area in which the dehumidifier is to be operated must be free of water 

intrusion or excessive fresh (outside) air infiltration. Before installing the Quest Dual Dehumidifier, water intrusion and air 

infiltration problems should be addressed or noted in calculations.

 

2. Registrations

The Quest Dual units conforms to unified standard UL 60335-2-40 and CSA standard C22.2.60335-2-40.
Patent: thermastor.com/patents

3. Specifications @ 80°F/60% RH

Unit:

4034220 110 Dual

4034230 150 Dual

Blower: 

(Tested with duct collars on)

365 CFM @ 0.0" WG 430 CFM @ 0.0" WG

Power: (Watts)

830

1300

Supply voltage:

115 VAC - 

 1 Phase - 60 Hz.

115 VAC -  

1 Phase - 60 Hz.

Current Draw: (Amps)

7.1

11.0

Energy Factor: (L/kWh)

2.8

2.3

Operating Temp:

56°F Min - 95°F Max

56°F Min - 95°F Max

Water Removal: (Pints/Day) 

Efficiency: (Pints/kWh)

110 

5.8

150 

4.8

Air Filter: (MERV-8 Nominal)

Size: 14" x 17.5" x 2"

Size: 14” x 17.5” x 2”

Power Cord: 

10’ 14/3 SJTW

NEMA 5-15P

NEMA 5-15P

Drain Connection:

3/4” Threaded NPT

3/4” Threaded NPT

Refrigerant Type: 

Refrigerant Amount:

R410A 

1lb. 9oz.

R410A 

1lb. 10oz.

Dimensions:

 

Width: 

Height: 

Length: 

Weight:

Unit    

Shipping 

14.5" 19" 

19.4" 25" 

26"  

35" 

85 lbs 

95 lbs

Unit  

Shipping 

14.5” 19” 

21”  

27” 

26”  

35” 

95 lbs 

100 lbs

Содержание quest 150 dual

Страница 1: ...d has passed a thorough inspection for quality of workmanship and function Installation Operation and Maintenance Instructions 4201 Lien Rd Madison WI 53704 Toll Free 1 877 420 1330 www QuestClimate c...

Страница 2: ...ion 5 4 1 Location 5 4 2 Electrical Requirements 5 4 3 Condensate Removal 6 4 4 Hanging Diagram 6 4 5 Ducting 7 4 5A Supply Duct Kit 7 4 5B Return Duct Kit 7 5 Controls 7 5 1 On board dehumidistat 7 5...

Страница 3: ...ed circuit DO NOT use the device as a bench or table DO NOT place the device directly on structural members Provide vibration isolation in order to minimize operational vibration and or noise A drain...

Страница 4: ...tandard UL 60335 2 40 and CSA standard C22 2 60335 2 40 Patent thermastor com patents 3 Specifications 80 F 60 RH Unit 4034220 110 Dual 4034230 150 Dual Blower Tested with duct collars on 365 CFM 0 0...

Страница 5: ...h or table DO NOT place the Quest Dual Dehumidifier directly on structural members Provide vibration isolation in order to minimize operational vibration and or noise A drain pan MUST be placed under...

Страница 6: ...y be installed if a lift is required to dispose of the condensate Optional parts list for information on the kit 4 4 Hanging Diagram A B B A A A A A B B P trap see section 4 5 for more info Bottom vie...

Страница 7: ...ble switch that closes when the relative humidity of the air in which it is located rises to the dial set point It opens when the RH drops 4 to 6 below the set point Approximate Humidity Levels Per Se...

Страница 8: ...of normal operation and no further oiling is required 7 Service WARNING Servicing the Quest Dual with its high pressure refrigerant system and high voltage circuitry presents a health hazard which co...

Страница 9: ...ressor run with fan switch AUTO 1 Unit unplugged or no power to outlet circuit breaker tripped 2 Humidity control set to Humid setting 3 Loose connection in internal wiring 4 Humidity control is defec...

Страница 10: ...riefly but cycles on and off 1 Loose connection in blower circuit 2 Obstruction prevents impeller rotation 3 Defective blower 4 Defective blower switch Evaporator coil frosted continuously low dehumid...

Страница 11: ...m info QuestClimate com Wiring Diagrams 115 VAC 60 Hz SINGLE PHASE BLK BLK BLU WHT GRN GRN YEL RED FAN SWITCH DEFROST THERMOSTATS IMPELLER COMPRESSOR 3 1 2 BLK BLK ORG S C R GRN FAN ON FAN AUTO DEHUMI...

Страница 12: ...9 Condenser 150 4026360 Impeller 110 4035463 Impeller 150 4033032 06 50mfd 370V Capacitor Compressor 4035235 04 7 5mfd 370V Capacitor Impeller 110 4035235 10 12mfd 370V Capacitor Impeller 150 4026221...

Страница 13: ...means The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unau...

Отзывы: