Quest Dry

Quest 110/150 Dual

Installation, Operation and Maintenance Instructions

This manual is provided to acquaint you with the 

dehumidifier so that installation, operation and maintenance 

can proceed successfully. Ultimate satisfaction depends on 

the quality of installation and a thorough understanding 

of this equipment. The dehumidifier is built around tested 

engineering principles and has passed a thorough inspection 

for quality of workmanship and function.

Installation, Operation and Maintenance Instructions

4201 Lien Rd 

Madison, WI 53704 

Toll-Free 1-877-420-1330

www.QuestClimate.com [email protected]

 

– Read and Save These Instructions –

Specifications subject to change without notice.

1

  

Features:
•  High capacity
•  High efficiency
•  Environmentally friendly
•  Small Footprint

TS-1175 

09/20 Rev. A

Water Removal Rates (Pints/Day) @ 80°F 60% (AHAM)

 

 

Dehumidifier 

Pints Removed  Gallons/Liters

 

110 Dual 

110 

13.75/52

150 Dual 

150 

18.75/71

Patent: thermastor.com/patents

Quest 110

Quest 150

Содержание quest 150 dual

Страница 1: ...d has passed a thorough inspection for quality of workmanship and function Installation Operation and Maintenance Instructions 4201 Lien Rd Madison WI 53704 Toll Free 1 877 420 1330 www QuestClimate c...

Страница 2: ...ion 5 4 1 Location 5 4 2 Electrical Requirements 5 4 3 Condensate Removal 6 4 4 Hanging Diagram 6 4 5 Ducting 7 4 5A Supply Duct Kit 7 4 5B Return Duct Kit 7 5 Controls 7 5 1 On board dehumidistat 7 5...

Страница 3: ...ed circuit DO NOT use the device as a bench or table DO NOT place the device directly on structural members Provide vibration isolation in order to minimize operational vibration and or noise A drain...

Страница 4: ...tandard UL 60335 2 40 and CSA standard C22 2 60335 2 40 Patent thermastor com patents 3 Specifications 80 F 60 RH Unit 4034220 110 Dual 4034230 150 Dual Blower Tested with duct collars on 365 CFM 0 0...

Страница 5: ...h or table DO NOT place the Quest Dual Dehumidifier directly on structural members Provide vibration isolation in order to minimize operational vibration and or noise A drain pan MUST be placed under...

Страница 6: ...y be installed if a lift is required to dispose of the condensate Optional parts list for information on the kit 4 4 Hanging Diagram A B B A A A A A B B P trap see section 4 5 for more info Bottom vie...

Страница 7: ...ble switch that closes when the relative humidity of the air in which it is located rises to the dial set point It opens when the RH drops 4 to 6 below the set point Approximate Humidity Levels Per Se...

Страница 8: ...of normal operation and no further oiling is required 7 Service WARNING Servicing the Quest Dual with its high pressure refrigerant system and high voltage circuitry presents a health hazard which co...

Страница 9: ...ressor run with fan switch AUTO 1 Unit unplugged or no power to outlet circuit breaker tripped 2 Humidity control set to Humid setting 3 Loose connection in internal wiring 4 Humidity control is defec...

Страница 10: ...riefly but cycles on and off 1 Loose connection in blower circuit 2 Obstruction prevents impeller rotation 3 Defective blower 4 Defective blower switch Evaporator coil frosted continuously low dehumid...

Страница 11: ...m info QuestClimate com Wiring Diagrams 115 VAC 60 Hz SINGLE PHASE BLK BLK BLU WHT GRN GRN YEL RED FAN SWITCH DEFROST THERMOSTATS IMPELLER COMPRESSOR 3 1 2 BLK BLK ORG S C R GRN FAN ON FAN AUTO DEHUMI...

Страница 12: ...9 Condenser 150 4026360 Impeller 110 4035463 Impeller 150 4033032 06 50mfd 370V Capacitor Compressor 4035235 04 7 5mfd 370V Capacitor Impeller 110 4035235 10 12mfd 370V Capacitor Impeller 150 4026221...

Страница 13: ...means The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unau...

Отзывы: