background image

1-877-420-1330

 

Quest 110/150 Dual 

Installation, Operation and Maintenance Instructions

13

www.QuestClimate.com

[email protected]

Quest Dual Dehumidifier Limited Warranty 

WARRANTOR: 
Therma-Stor LLC 

4201 Lien Rd 

Madison, WI 53704 

Telephone: 1-800-533-7533
WHO IS COVERED: This warranty extends only to the original end-user of the Quest Dual dehumidifier, and may not 

be assigned or transferred.
FIRST YEAR WARRANTY: Therma-Stor LLC warrants that, for one (1) year the Quest Dual dehumidifier will operate 

free from any defects in materials and workmanship, or Therma-Stor LLC will, at its option, repair or replace the 

defective part(s), free of any charge.
SECOND THROUGH FIFTH YEAR WARRANTY: Therma-Stor LLC further warrants that for a period of five (5) 

years, the condenser, evaporator, and compressor of the Quest Dual dehumidifier will operate free of any defects in 

material or workmanship, or Therma-Stor LLC, at its option, will repair or replace the defective part(s), provided that all 

labor and transportation charges for the part(s) shall be borne by the end-user.
END-USER RESPONSIBILITIES: Warranty service must be performed by a Servicer authorized by Therma-Stor LLC. 

If the end-user is unable to locate or obtain warranty service from an authorized Servicer, he should call Therma-Stor 

LLC at the above number and ask for the Therma-Stor LLC Service Department, which will then arrange for covered 

warranty service. Warranty service will be performed during normal working hours.
The End-user must present proof of purchase (lease) upon request, by use of the warranty card or other reasonable and 

reliable means. The end-user is responsible for normal care. This warranty does not cover any defect, malfunction, etc. 

resulting from misuse, abuse, lack of normal care, corrosion, freezing, tampering, modification, unauthorized or improper 

repair or installation, accident, acts of nature or any other cause beyond Therma-Stor LLC's reasonable control.
LIMITATIONS AND EXCLUSIONS: If any Quest Dual Dehumidifier part is repaired or replaced, the new part shall 

be warranted for only the remainder of the original warranty period applicable thereto (but all warranty periods will 

be extended by the period of time, if any, that the Quest Dual Dehumidifier is out of service while awaiting covered 

warranty service).
UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE Quest Dual DEHUMIDIFIER 

OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING MERCHANTABILITY 

AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL WARRANTIES MADE BY 

THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE AGAINST THERMA-STOR 

LLC BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR LLC, IN CONNECTION 

WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY Quest Dual DEHUMIDIFIER 

OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR 

CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE END-USER 

SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF USE OR DAMAGE 

TO ANY REAL OR PERSONAL PROPERTY.
Some states do not allow limitations on how long an implied warranty lasts, and some do not allow the exclusion or 

limitation of incidental or consequential damages, so one or both of these limitation may not apply to you.
LEGAL RIGHTS: This warranty gives you specific legal rights, and you may also have other rights which vary from state 

to state.

Содержание quest 150 dual

Страница 1: ...d has passed a thorough inspection for quality of workmanship and function Installation Operation and Maintenance Instructions 4201 Lien Rd Madison WI 53704 Toll Free 1 877 420 1330 www QuestClimate c...

Страница 2: ...ion 5 4 1 Location 5 4 2 Electrical Requirements 5 4 3 Condensate Removal 6 4 4 Hanging Diagram 6 4 5 Ducting 7 4 5A Supply Duct Kit 7 4 5B Return Duct Kit 7 5 Controls 7 5 1 On board dehumidistat 7 5...

Страница 3: ...ed circuit DO NOT use the device as a bench or table DO NOT place the device directly on structural members Provide vibration isolation in order to minimize operational vibration and or noise A drain...

Страница 4: ...tandard UL 60335 2 40 and CSA standard C22 2 60335 2 40 Patent thermastor com patents 3 Specifications 80 F 60 RH Unit 4034220 110 Dual 4034230 150 Dual Blower Tested with duct collars on 365 CFM 0 0...

Страница 5: ...h or table DO NOT place the Quest Dual Dehumidifier directly on structural members Provide vibration isolation in order to minimize operational vibration and or noise A drain pan MUST be placed under...

Страница 6: ...y be installed if a lift is required to dispose of the condensate Optional parts list for information on the kit 4 4 Hanging Diagram A B B A A A A A B B P trap see section 4 5 for more info Bottom vie...

Страница 7: ...ble switch that closes when the relative humidity of the air in which it is located rises to the dial set point It opens when the RH drops 4 to 6 below the set point Approximate Humidity Levels Per Se...

Страница 8: ...of normal operation and no further oiling is required 7 Service WARNING Servicing the Quest Dual with its high pressure refrigerant system and high voltage circuitry presents a health hazard which co...

Страница 9: ...ressor run with fan switch AUTO 1 Unit unplugged or no power to outlet circuit breaker tripped 2 Humidity control set to Humid setting 3 Loose connection in internal wiring 4 Humidity control is defec...

Страница 10: ...riefly but cycles on and off 1 Loose connection in blower circuit 2 Obstruction prevents impeller rotation 3 Defective blower 4 Defective blower switch Evaporator coil frosted continuously low dehumid...

Страница 11: ...m info QuestClimate com Wiring Diagrams 115 VAC 60 Hz SINGLE PHASE BLK BLK BLU WHT GRN GRN YEL RED FAN SWITCH DEFROST THERMOSTATS IMPELLER COMPRESSOR 3 1 2 BLK BLK ORG S C R GRN FAN ON FAN AUTO DEHUMI...

Страница 12: ...9 Condenser 150 4026360 Impeller 110 4035463 Impeller 150 4033032 06 50mfd 370V Capacitor Compressor 4035235 04 7 5mfd 370V Capacitor Impeller 110 4035235 10 12mfd 370V Capacitor Impeller 150 4026221...

Страница 13: ...means The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unau...

Отзывы: