Quest 110/150 Dual 

Installation, Operation and Maintenance Instructions

5

www.QuestClimate.com

[email protected]

4. Installation 

4.1 Location

The Quest Dual Dehumidifier can be installed in a variety of locations to meet the owner’s needs as listed below. In all 

cases keep the following cautions in mind:
•  It is designed to be installed INDOORS IN A SPACE THAT IS PROTECTED FROM RAIN AND FLOODING.
•  Install the unit with space to access the back and side panels for maintenance and service and also to allow easy 

access to the filter cover panel. DO NOT INSTALL UNIT WITH THE FRONT PANEL OR FILTER COVER 

PANEL INACCESSIBLE.

•  Avoid discharging the air directly at people, or over the water in pool areas.
•  Be certain there is NO chance the unit could fall into water or be splashed and that it is plugged into a GROUND 

FAULT INTERRUPTER. 

•  DO NOT use the Quest Dual Dehumidifier as a bench or table. 
•  DO NOT place the Quest Dual Dehumidifier directly on structural members. Provide vibration isolation in order to 

minimize operational vibration and/or noise.

•  A drain pan MUST be placed under the unit if installed above an area where water leakage could cause damage. 
•  Maintain a minimum 1ft. (.3m) clearance to avoid obstructing the air return and supply.
•  Place the Quest Dual Dehumidifier on supports that raise the base of the unit 2.5” above the drain pan to a P-trap 

can be installed. See Section 4.3. 

•  The Quest Dual Dehumidifier may be suspended with steel hanger, straps, or a suitable alternative from structural 

members, unit must be supported from underneath. Don’t hang from sides or ends. See section 4.4 

4.2 Electrical Requirements 

The Quest Dual Dehumidifier plugs into NEMA rated Receptacles. The amp draws for each unit under normal operating 

conditions are listed on page 4. A ground fault interrupter protected circuit is required. 

 CAUTION!  For proper drainage, the unit must be mounted so the drain outlet is at least 4” 

above the floor drain, and must be fully supported under the base.

Содержание quest 150 dual

Страница 1: ...d has passed a thorough inspection for quality of workmanship and function Installation Operation and Maintenance Instructions 4201 Lien Rd Madison WI 53704 Toll Free 1 877 420 1330 www QuestClimate c...

Страница 2: ...ion 5 4 1 Location 5 4 2 Electrical Requirements 5 4 3 Condensate Removal 6 4 4 Hanging Diagram 6 4 5 Ducting 7 4 5A Supply Duct Kit 7 4 5B Return Duct Kit 7 5 Controls 7 5 1 On board dehumidistat 7 5...

Страница 3: ...ed circuit DO NOT use the device as a bench or table DO NOT place the device directly on structural members Provide vibration isolation in order to minimize operational vibration and or noise A drain...

Страница 4: ...tandard UL 60335 2 40 and CSA standard C22 2 60335 2 40 Patent thermastor com patents 3 Specifications 80 F 60 RH Unit 4034220 110 Dual 4034230 150 Dual Blower Tested with duct collars on 365 CFM 0 0...

Страница 5: ...h or table DO NOT place the Quest Dual Dehumidifier directly on structural members Provide vibration isolation in order to minimize operational vibration and or noise A drain pan MUST be placed under...

Страница 6: ...y be installed if a lift is required to dispose of the condensate Optional parts list for information on the kit 4 4 Hanging Diagram A B B A A A A A B B P trap see section 4 5 for more info Bottom vie...

Страница 7: ...ble switch that closes when the relative humidity of the air in which it is located rises to the dial set point It opens when the RH drops 4 to 6 below the set point Approximate Humidity Levels Per Se...

Страница 8: ...of normal operation and no further oiling is required 7 Service WARNING Servicing the Quest Dual with its high pressure refrigerant system and high voltage circuitry presents a health hazard which co...

Страница 9: ...ressor run with fan switch AUTO 1 Unit unplugged or no power to outlet circuit breaker tripped 2 Humidity control set to Humid setting 3 Loose connection in internal wiring 4 Humidity control is defec...

Страница 10: ...riefly but cycles on and off 1 Loose connection in blower circuit 2 Obstruction prevents impeller rotation 3 Defective blower 4 Defective blower switch Evaporator coil frosted continuously low dehumid...

Страница 11: ...m info QuestClimate com Wiring Diagrams 115 VAC 60 Hz SINGLE PHASE BLK BLK BLU WHT GRN GRN YEL RED FAN SWITCH DEFROST THERMOSTATS IMPELLER COMPRESSOR 3 1 2 BLK BLK ORG S C R GRN FAN ON FAN AUTO DEHUMI...

Страница 12: ...9 Condenser 150 4026360 Impeller 110 4035463 Impeller 150 4033032 06 50mfd 370V Capacitor Compressor 4035235 04 7 5mfd 370V Capacitor Impeller 110 4035235 10 12mfd 370V Capacitor Impeller 150 4026221...

Страница 13: ...means The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unau...

Отзывы: