background image

8

www.UsePhoenix.com  •  [email protected]

Toll-Free 1-800-533-7533

Specifications subject to change without notice.

6 Service Parts

Item 

Description 

Qty 

Part No.

Top Cover 

4028583

Top Cover Hinge 

4027267

Wheel 12” Gray 

4026304

Cotter Pin 3/32” 

1284404

Air Filter 1.75 x 15.5 x 19.5 

4021475

Hose Plastic 0.56 ID x 24 

4029894

Hose Plastic 0.38 ID 

4021909

Hose Plastic 0.25ID x 33 

4024916

Coupling Body 0.25 Tube 

4024910

10 

Coupling Insert 0.38 Tube 

4023080

11 

Control Board 

4030083

12 

Capacitor Compressor

 45mfd 370V

 1 

4033032-05

13 

Capacitor Impeller 

15mfd 370V

 1  4033031-07

14 Thermistor 

1  4031279

15 Cord 

1  4032297

16 

TOS, 8.2 KBTU, R410A 

4029182

17 

Overload Compressor 

4029183

18 

Evaporator Coil 

4028565

19 

Condenser Coil 

4028566

20 

Condensate Pump 

4034605-01

21 

Fan Motorized Impeller 

4026657

22 

Inlet Ring 

4028564

23 

Wire Duct Collar 

4028593

24 

Filter Drier (not shown) 

4029510

25 

Wire Harness (not shown) 

4030084

26 

Handle 

4026094

27 

Bolt M10-1.5 X 35 

1177792

28 

Washer M10 X 30 

4025517

29 

Hex Lock Nut M10-1.5 

1223780

1

3,4

6

7,8,9,10

11

15

16,17

18

20

21

23

23

26,27,28,29

5

12

13

14

2

20

Содержание Phoenix 200 HT

Страница 1: ...Faster drying and superior static pressure for ducting Multiple Ducting Options 12 intake 10 exhaust Solid State Controls Easy to read and operate Recessed 12 Wheels Allows greater maneuverability on...

Страница 2: ...t from walls and other obstructions to air flow Table of Contents Introduction 1 1 Specifications 2 2 Operation 2 2 1 Transporting the Phoenix 200HT 2 2 2 Location 2 2 3 Electrical Requirements 3 2 4...

Страница 3: ...e plugged in dehu midifier to rest 15 minutes before the final purge 2 8 Hour Meter The digital hour meter displays the amount of time the dehumidifier has been turned on to the tenth of an hour The h...

Страница 4: ...an alternative to reduce biological growth is to flush the unit with a bio fungicide that is approved for use with copper aluminum and polyethylene To flush 1 Run the hose to a drain 2 Plug in the un...

Страница 5: ...but not as much as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibration 3 Unit has entered defrost cycle 4 Air filter dirty 5 Defecti...

Страница 6: ...ately weighed in If any of the old charge is left in the system it must be removed before weighing in the new charge Refer to the unit nameplate for the correct charge weight and refrigerant type 4 7...

Страница 7: ...www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 5 Wiring Diagram LL Therma Stor...

Страница 8: ...e 1 4023080 11 Control Board 1 4030083 12 Capacitor Compressor 45mfd 370V 1 4033032 05 13 Capacitor Impeller 15mfd 370V 1 4033031 07 14 Thermistor 1 4031279 15 Cord 1 4032297 16 TOS 8 2 KBTU R410A 1 4...

Страница 9: ...www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 This page intentionally left blank...

Страница 10: ...anty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts o...

Отзывы: