background image

10

www.UsePhoenix.com  •  [email protected]

Toll-Free 1-800-533-7533

Phoenix 200HT Dehumidifier Limited Warranty

Warrantor:

Therma-Stor LLC 

4201 Lien Rd 

Madison, WI 53704 

1-800-533-7533

Who Is Covered:

 This warranty extends only to the original end-user of the Phoenix 200HT dehumidifier, 

and may not be assigned or transferred.

First Year Warranty:

 Therma-Stor warrants that, for one (1) year the Phoenix 200HT dehumidifier will 

operate free from any defects in materials and workmanship, or Therma-Stor will, at its option, repair or 

replace the defective part(s), free of any charge.

Second Through Fifth Year Warranty

: Therma-Stor further warrants that for a period of five (5) years, 

the condenser, evaporator, and compressor of the Phoenix 200HT dehumidifier will operate free of any 

defects in material or workmanship, or Therma-Stor, at its option, will repair or replace the defective 

part(s), provided that all labor and transportation charges for the part(s) shall be borne by the end-user.

End-User Responsibilities:

 Warranty service must be performed by a Servicer authorized by Therma-Stor. 

If the end-user is unable to locate or obtain warranty service from an authorized Servicer, he should call 

Therma-Stor at the above number and ask for the Therma-Stor Service Department., which will then 

arrange for covered warranty service. Warranty service will be performed during normal working hours.

The end-user must present proof of purchase (lease) upon request, by reasonable and reliable means. 

The end-user is responsible for normal care. This warranty does not cover any defect, malfunction, 

etc. resulting from misuse, abuse, lack of normal care, corrosion, freezing, tampering, modification, 

unauthorized or improper repair or installation, accident, acts of nature or any other cause beyond 

Therma-Stor’ reasonable control.

Limitations and Exclusions

: If any Phoenix 200HT Dehumidifier part is repaired or replaced, the new 

part shall be warranted for only the remainder of the original warranty period applicable thereto (but all 

warranty periods will be extended by the period of time, if any, that the Phoenix 200HT Dehumidifier is 

out of service while awaiting covered warranty service).

UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE Phoenix 200HT DEHUMIDIFIER 

OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING MERCHANTABILITY AND 

FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL WARRANTIES MADE BY Therma-Stor 

ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE AGAINST Therma-Stor BASED ON ANY ORAL 

WARRANTY. IN NO EVENT SHALL Therma-Stor, IN CONNECTION WITH THE SALE, INSTALLATION, USE, 

REPAIR OR REPLACEMENT OF ANY Phoenix 200HT DEHUMIDIFIER OR PART THEREOF BE LIABLE UNDER 

ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT 

LIMITATION WATER DAMAGE (THE END-USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST 

PROFITS, DELAY, OR LOSS OF USE OR DAMAGE TO ANY REAL OR PERSONAL PROPERTY.

Some states do not allow limitations on how long an implied warranty lasts, and some do not allow the 

exclusion or limitation of incidental or consequential damages, so one or both of these limitation may not 

apply to you.

Legal Rights:

 This warranty gives you specific legal rights, and you may also have other rights which vary 

from state to state.

Содержание Phoenix 200 HT

Страница 1: ...Faster drying and superior static pressure for ducting Multiple Ducting Options 12 intake 10 exhaust Solid State Controls Easy to read and operate Recessed 12 Wheels Allows greater maneuverability on...

Страница 2: ...t from walls and other obstructions to air flow Table of Contents Introduction 1 1 Specifications 2 2 Operation 2 2 1 Transporting the Phoenix 200HT 2 2 2 Location 2 2 3 Electrical Requirements 3 2 4...

Страница 3: ...e plugged in dehu midifier to rest 15 minutes before the final purge 2 8 Hour Meter The digital hour meter displays the amount of time the dehumidifier has been turned on to the tenth of an hour The h...

Страница 4: ...an alternative to reduce biological growth is to flush the unit with a bio fungicide that is approved for use with copper aluminum and polyethylene To flush 1 Run the hose to a drain 2 Plug in the un...

Страница 5: ...but not as much as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibration 3 Unit has entered defrost cycle 4 Air filter dirty 5 Defecti...

Страница 6: ...ately weighed in If any of the old charge is left in the system it must be removed before weighing in the new charge Refer to the unit nameplate for the correct charge weight and refrigerant type 4 7...

Страница 7: ...www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 5 Wiring Diagram LL Therma Stor...

Страница 8: ...e 1 4023080 11 Control Board 1 4030083 12 Capacitor Compressor 45mfd 370V 1 4033032 05 13 Capacitor Impeller 15mfd 370V 1 4033031 07 14 Thermistor 1 4031279 15 Cord 1 4032297 16 TOS 8 2 KBTU R410A 1 4...

Страница 9: ...www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 This page intentionally left blank...

Страница 10: ...anty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts o...

Отзывы: