Therma-Stor Phoenix 200 HT Скачать руководство пользователя страница 2

2

www.UsePhoenix.com  •  [email protected]

Toll-Free 1-800-533-7533

1 Specifications

Part No.

 

4029970

Power

 

110-120 Vac, 7.2 amps

Water 

135 pints/day @ AHAM (80°F, 60%) 

Removal

Refrigerant  

2 lbs. 2 oz. R410a 

Charge

 

Blower

 

380 CFM 

 

Internal Condensate Pump with 20’ lift, 

 

30’ vinyl hose

Operating  

33°F to 125°F 

Range

  

Filters

 

16” x 20” x 2” Pleated Media MERV-11 

  

Duct  

Intake – 12” Flex-Duct

 

Options 

Exhaust – 10” Lay-Flat 

  

Warranty

 

Five years; 

 

First year 100% of Parts and Labor 

 

Second-fifth year 100% of Parts of sealed 

 

refrigeration system.

Dimensions   

Width 20”, Height 40”, Depth 23” 

Weight  

130 lbs. 

2 Operation

2.1 Transporting the Phoenix 200HT 

The Phoenix 200HT must always be upright when 

transported by vehicle. It may be tipped on to its handle and 

back for loading and moving by hand.

2.2 Location

Note the following precautions when locating the Phoenix 
200HT:

•  It is designed to be used 

INDOORS ONLY.

•  If used in a wet area, plug it into a 

GROUND FAULT 

INTERRUPTER

.

• 

DO NOT

 use the Phoenix 200HT as a bench or table.

 • It must always be used in the upright position.
•  The air inlet on top & the side outlet must be at least  

1 foot from walls and other obstructions to air flow.

 

Table of Contents

Introduction

 .............................................................................1 

1.   Specifications

 ..................................................................2

2.   Operation

 .........................................................................2

 

2.1 Transporting the Phoenix 200HT .............................2

 

2.2 Location .....................................................................2

 

2.3 Electrical Requirements ............................................3

 

2.4 Condensate Removal ................................................3

 

2.5 Ducting .......................................................................3

 

2.6 Power Button .............................................................3

 

2.7 Pump Purge Button ...................................................3

 

2.8 Hour Meter .................................................................3

 

2.9 Hours Button .............................................................3

 

2.10 Defrost Light ............................................................3

 

2.11 Low Pressure Protection .........................................3

 

2.12 Defrost Cycle ...........................................................3

 

2.13 Temperature Specific Operation ............................4

3.   Maintenance

 ....................................................................4

 

3.1 Air Filter ......................................................................4

 

3.2 Storage .......................................................................4

4.   Service

 ..............................................................................4

 

4.1 Technical Description ................................................4

 

4.2 Troubleshooting .........................................................5

 

4.3 Air Mover Replacement .............................................5

 

4.4 Thermistor Replacement ..........................................5

 

4.5 Condensate Pump Replacement .............................6

 

 4.6 Refrigerant Charging .................................................6

 

4.7 Compressor/Capacitor Replacement ......................6

 

4.8 Gravity Drain Option ..................................................6

5.   Wiring Diagram

 ...............................................................7

6.   Service Parts List

 .............................................................8

7. Warranty

 .........................................................................10

Serial No. ___________________________

Purchase Date ______/______/_____

Dealer’s Name ___________________________________

Read the operation and maintenance instructions 
carefully before using this unit. Proper adherence to these 
instructions is essential to obtain maximum benefit from 
your Phoenix 200HT dehumidifier.

• It is designed to be used 

INDOORS ONLY

.

• If used in a wet area, plug it into a 

GROUND FAULT  

INTERRUPTER

.

• 

DO NOT

 use the Phoenix 200HT as a bench or table.

• It must always be used in the upright position.

Содержание Phoenix 200 HT

Страница 1: ...Faster drying and superior static pressure for ducting Multiple Ducting Options 12 intake 10 exhaust Solid State Controls Easy to read and operate Recessed 12 Wheels Allows greater maneuverability on...

Страница 2: ...t from walls and other obstructions to air flow Table of Contents Introduction 1 1 Specifications 2 2 Operation 2 2 1 Transporting the Phoenix 200HT 2 2 2 Location 2 2 3 Electrical Requirements 3 2 4...

Страница 3: ...e plugged in dehu midifier to rest 15 minutes before the final purge 2 8 Hour Meter The digital hour meter displays the amount of time the dehumidifier has been turned on to the tenth of an hour The h...

Страница 4: ...an alternative to reduce biological growth is to flush the unit with a bio fungicide that is approved for use with copper aluminum and polyethylene To flush 1 Run the hose to a drain 2 Plug in the un...

Страница 5: ...but not as much as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibration 3 Unit has entered defrost cycle 4 Air filter dirty 5 Defecti...

Страница 6: ...ately weighed in If any of the old charge is left in the system it must be removed before weighing in the new charge Refer to the unit nameplate for the correct charge weight and refrigerant type 4 7...

Страница 7: ...www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 5 Wiring Diagram LL Therma Stor...

Страница 8: ...e 1 4023080 11 Control Board 1 4030083 12 Capacitor Compressor 45mfd 370V 1 4033032 05 13 Capacitor Impeller 15mfd 370V 1 4033031 07 14 Thermistor 1 4031279 15 Cord 1 4032297 16 TOS 8 2 KBTU R410A 1 4...

Страница 9: ...www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 This page intentionally left blank...

Страница 10: ...anty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts o...

Отзывы: