background image

AllClear

 Series

A

B

C

D

E

F

G

H

I

J

K

B

G

H

C

Replacement Parts

 

ALLCLEAR

 FILTER:

MODEL

PRESSURE INDICATOR 

O-RING

FILTER TOP W/QUARTZ 

SLEEVE

FITTING 

KIT

UV TRANSFORMER 

W/UV-C BULB

O-RING FOR UV 

TRANSFORMER

AllClear™ 1200

#120987

#120897

#120882

#120894

#120849

AllClear™ 2400

#120898

#120883

#120895

MODEL

REPLACEMENT 

UV BULB

FILTER PAD 

SET

FILTER 

CLAMP

FILTER TOP 

O-RING

FILTER BOTTOM W/FILTER 

PAD TRAY & BIOBALLS

QUARTZ 

SLEEVE

AllClear™ 1200

#110408

#120874

N/A

#120878

#120865

#120870

AllClear™ 2400

#110306

#120875

#120890

#120879

#120866

#120871

* Note: For your safety, the AllClear™ Filter UV will not operate unless the UV transformer 

is securely connected to the filter.

 

If water is not clear, check the following:

  • Check the viewing window to ensure the UV-C bulb is lit. 
  • Replace UV-C bulb if it has not been replaced in the past year, even if it is lit.
  • Check that the quartz sleeve is clean. 
  •  Verify that the proper amount of water is flowing through the filter. See recommendation for proper 

water flow on page 3. 

  • Verify that filter media is not plugged with debris or needs cleaning.
Loss of water flow, check the following:
  • Verify pump is not plugged with debris.
  • Verify filter media is not plugged with debris.
  • Verify filter is not leaking causing a loss of pressure.
Filter is leaking, check the following:
  •  Verify that the proper amount of water is flowing through the filter. See recommendation for proper 

water flow on page 3. 

  • Verify O-rings are seated correctly or replace if warn.
  • Verify filter canister has not been damaged. 

AllClear™ Pressurized Filters carry a 5-year warranty. The Pond Guy® will repair or replace any units found 

to be defective. This limited warranty is extended exclusively to the original purchaser and begins from 

the date of original purchase receipt. The UV-C bulb, filter media and o-rings are wearable items and are 

not covered by this warranty. Abuse or misuse of this product or power cord alterations void all warranty. 

Please call for a Return Authorization Number prior to returning product by calling our Customer Care 

Department at 866-766-3435. Failure to request an RMA number may result in delay or dismissal of your 

warranty claim.

A

D

J

K

I

E

Optional - TrueRock™ Medium Boulder Cover

To camouflage and protect the AllClear™ PLUS Filter from 
the outside elements use a TrueRock™ Medium Boulder 
Cover (#510332).

*  Note: On 1200 filter, four canister buckles are used for securing instead of one canister clamp. Also, 1200 filter includes  

2 filter pads instead of 3.

F

thepondguy.com  |  866-POND-HELP (766-3435)  

15425 Chets Way | Armada, MI 48005

10

11

Содержание AllClear Series

Страница 1: ...odels AllClear 1200 Item 120830 AllClear 2400 Item 120831 NOTES ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ________________________...

Страница 2: ...g The AllClear Filter is NOT suitable for use in swimming pools swimming ponds or other situations where bodily contact is made with the water Although the AllClear Filter is designed for outdoor use it should never be submerged in water Avoid contact with the UV C light Light omitted can be harmful to the eyes and skin CAUTION To reduce the risk of equipment damage or failure DO NOT place the All...

Страница 3: ...ittings to the inlet and outlet of the AllClear Filter with the compression ring Note The o rings should be between the filter housing and the step down fitting to create a watertight seal when secure Step 5 Cut the Fittings CUT step down fittings down to the largest connection that will work with your plumbing Step down fittings offer options for use with 1 1 1 4 and 1 1 2 plumbing Note AllClear ...

Страница 4: ...filter canister clamp on model 1200 unlatch the four buckles Gently pull off the filter canister top and set aside Remove filter pads Step 1 Disconnect Plumbing DISCONNECT plumbing by unscrewing the step down fittings from the AllClear Filter Step 3 Restore Power RINSE media pads with a bucket of pond water Do not rinse BioBalls media except for winter storage unless BioBalls media are plugged wit...

Страница 5: ...emove Bracket REMOVE the screws securing the power cord retaining bracket Step 3 Unscrew UV Transformer UNSCREW UV Transformer and gently pull out the UV transformer and bulb Step 1 Remove Access Hatch REMOVE the screws securing the access hatch Then gently lift to separate Step 4 Replace the Bulb PULL gently on the base of the UV C bulb to remove Insert new bulb and reassemble unit DO NOT touch t...

Страница 6: ...aning Loss of water flow check the following Verify pump is not plugged with debris Verify filter media is not plugged with debris Verify filter is not leaking causing a loss of pressure Filter is leaking check the following Verify that the proper amount of water is flowing through the filter See recommendation for proper water flow on page 3 Verify O rings are seated correctly or replace if warn ...