background image

Package Contents

 

ALLCLEAR

 FILTER:

Please read these instructions thoroughly before use. Failure to follow instructions may 

result in equipment damage or failure, losses, injury or death.

 DANGER: 

To avoid possible electric shock:
•  If the power cord has been damaged, DO NOT operate, AllClear™ UV unit should be replaced. 
•  Prior to installation, inspect the quartz sleeve and UV-C bulb to ensure there was no damage during 

transportation. 

•  After installation, the AllClear™ Filter should be examined to ensure there is no water on parts not 

intended to be wet. 

•  If the AllClear™ Filter shows signs of any water leakage, immediately unplug it from the power source.
•  If the AllClear™ Filter falls into the water, DO NOT reach for it. First unplug and then retrieve it.
•  Close supervision is necessary when the unit is used by or near children.

 WARNING: 

To reduce the risk of electric shock:
•  Connect only to a properly grounded receptacle, which is serviced by a Ground Fault Circuit 

Interrupter and never remove the ground pin from the plug. 

•  Provide a “drip loop” for the power cord. This is a loop in the cord below the level of the receptacle or 

plug that prevents water from traveling along the cord in the direction of the receptacle. 

•  ALWAYS unplug the AllClear™ Filter from power source when it is not in use, and before installing, 

removing or servicing the AllClear™ Filter components.

•  If an extension cord is necessary, a cord with a proper rating should be used. A cord may overheat if 

the cord is rated for less amperes or watts than the unit rating.

•  DO NOT immerse the AllClear™ Filter or plug in water or attempt to use a wet plug. 
•  The AllClear™ Filter is NOT suitable for use in swimming pools, swimming ponds, or other situations 

where bodily contact is made with the water. Although the AllClear™ Filter is designed for outdoor 

use, it should never be submerged in water.

Avoid contact with the UV-C light. Light omitted can be harmful to the eyes and skin. 

 CAUTION: 

To reduce the risk of equipment damage or failure:
•  DO NOT place the AllClear™ Filter in direct sunshine.
•  DO NOT place the AllClear™ Filter near flammable or other dangerous materials or objects.
•  ALWAYS unplug the unit if there is no water running through it to prevent over heating.
•  The AllClear™ Filter is NOT submersible; do not place the AllClear™ Filter where it might contact or fall 

into the water.

•  DO NOT operate during freezing conditions. Drain, disconnect and store the AllClear™ Filter in a 

protected location. 

•  DO NOT operate the AllClear™ Filter with a pump larger than the maximum flow rate indicated by 

the filter specifications.  Operating with a pump larger than recommended can reduce the filters 

effectiveness and cause damage to the filter or UV and will NOT be covered under warranty.

  

The Pond Guy® is not responsible for equipment damage or failure, losses, injury or death 

resulting from failure to follow safety precautions, misuse or abuse of equipment.

MODEL

POWER

UV

MAX FLOW 

RATE

MAX POND SIZE 

(GALLONS)

PLUMBING SIZE  

(STEP DOWN BARB FITTING)

POWER 

CORD 

LENGTH

AllClear™ 1200

120V / 60 Hz

7 Watts

600 GPH

1,200

1”

16’

AllClear™ 2400

120V / 60 Hz

9 Watts

1,600 GPH

2,400

1”, 1¼”, 1½”

*  Note: On 1200 filter, four canister buckles are used for securing instead of one canister clamp. Also, 1200 filter includes 2 

filter pads instead of 3.

AllClear

 PLUS Series

A

B

C

B

A

C

thepondguy.com  |  866-POND-HELP (766-3435)  

15425 Chets Way | Armada, MI 48005

2

3

Содержание AllClear Series

Страница 1: ...odels AllClear 1200 Item 120830 AllClear 2400 Item 120831 NOTES ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ________________________...

Страница 2: ...g The AllClear Filter is NOT suitable for use in swimming pools swimming ponds or other situations where bodily contact is made with the water Although the AllClear Filter is designed for outdoor use it should never be submerged in water Avoid contact with the UV C light Light omitted can be harmful to the eyes and skin CAUTION To reduce the risk of equipment damage or failure DO NOT place the All...

Страница 3: ...ittings to the inlet and outlet of the AllClear Filter with the compression ring Note The o rings should be between the filter housing and the step down fitting to create a watertight seal when secure Step 5 Cut the Fittings CUT step down fittings down to the largest connection that will work with your plumbing Step down fittings offer options for use with 1 1 1 4 and 1 1 2 plumbing Note AllClear ...

Страница 4: ...filter canister clamp on model 1200 unlatch the four buckles Gently pull off the filter canister top and set aside Remove filter pads Step 1 Disconnect Plumbing DISCONNECT plumbing by unscrewing the step down fittings from the AllClear Filter Step 3 Restore Power RINSE media pads with a bucket of pond water Do not rinse BioBalls media except for winter storage unless BioBalls media are plugged wit...

Страница 5: ...emove Bracket REMOVE the screws securing the power cord retaining bracket Step 3 Unscrew UV Transformer UNSCREW UV Transformer and gently pull out the UV transformer and bulb Step 1 Remove Access Hatch REMOVE the screws securing the access hatch Then gently lift to separate Step 4 Replace the Bulb PULL gently on the base of the UV C bulb to remove Insert new bulb and reassemble unit DO NOT touch t...

Страница 6: ...aning Loss of water flow check the following Verify pump is not plugged with debris Verify filter media is not plugged with debris Verify filter is not leaking causing a loss of pressure Filter is leaking check the following Verify that the proper amount of water is flowing through the filter See recommendation for proper water flow on page 3 Verify O rings are seated correctly or replace if warn ...