06/2021 V 1.0
PORTRAIT SLIDER
1950mm
Header Bar
O
ff
set
27mm
25mm
9mm
15mm
Outside of
Enclosure
02/14
Measure 1950mm up from the
floor/tray. Mark this distance on the
wall. This is the Header Bar height.
Use the Header Bar distance noted in
Step 02 to help mark the Header Bar
Bracket hole positions on both walls
using the dimensions shown below.
Drill holes with a 6mm high quality drill
bit for a clean and precise hole.
Fully insert the wall plugs.
Install the Header Bar Brackets.
Adjust the Glass Clamp for a 10mm
Panel by adjusting the Grub Screws.
Ensure that the Glass Clamps are
parallel.
Clean the top section of the Glass Door
on both sides before fixing the Glass
Clamp.
Professional Tip
If drilling ceramic tiles, place
masking tape on the tiles before
marking and drill through the
tape to prevent the drill bit from
skidding.
DO NOT use Hammer Action as
this will break the tiles.
05
06
07
08
10mm