10
In general, it is always a good idea to filter the water. A water filter, if it is of the
proper type, can remove taste and odors as well as particles. Where water is very
hard, softened water may result in white, mushy cubes that stick together.
NOTE: Deionized water is not recommended.
The ice maker must be installed with all electrical, water and drain connections in
accordance with state and local codes.
The unit should be located on a firm and level surface. It is important for the ice
maker to be leveled in order to work properly. If needed, you can adjust the height
of the ice maker by adjusting the feet. See the “Leveling the Ice Maker” section.
A standard electrical supply (120 VAC only, 60 Hz, 15 A), properly grounded in
accordance with the National Electrical Code and local codes and ordinances is
required.
The MIM70 ice maker can be used as a built-in appliance too.
16.7
3/5
3/5
4
1
1
/
2
21
INSTALLATION CLEARANCE
TOP VIEW (1:10) (in.)
2-1/2
Normal operating ambient temperature should be between 55
℉
(13
℃
) to 90
℉
(32
℃
). Normal operating water temperature should be between 41
℉
(5
℃
)
and 77
℉
(25
℃
). Operation of the icemaker for extended periods out side of
these normal temperature ranges may affect production capacity.