AMC-400 Series Digital Transmitter with Smart Sensor 2
33
Note:
When the gas sensor needs calibration or service the display will alternate between the
reading value and the letters “
CAL
” and/or “
SEr
”.
Warning:
When performing calibration the results are not saved in Smart Sensor 2 until
successful Span procedure has been completed. Powering off unit after Zero
procedure and before completing a successful Span procedure will result in calibration
information being lost. Also failed Span procedure due to user abort or procedure limit
checking leaves the unit with unstable calibration information. It is important to
complete a successful SPAN procedure for unit to function properly.
Caution:
- Only qualified personnel should perform the actual calibration.
- Users new to gas calibration are advised to consult with Armstrong Monitoring
The Armstrong Monitoring Corporation offers the following calibration plans:
1. Factory pre-calibrated exchange replacement smart sensor 2 modules.
2. On site installation by Armstrong Monitoring.
3. On site calibration by Armstrong Monitoring.
4. Training by Armstrong Monitoring for end users.
For additional details please refer to CONTACT INFORMATION
.