User Manual / Technical Manual - Safety
9 of 49
• The disposable set should not be used for longer than 24 hours.
• Only use a syringe at an injection point at the end of the patient line.
After operation
• The heating surface of the warming module and the cassette of the disposable set can get quite
warm when heating cold IV fluids/blood at high flow rates. Wait a few seconds after stopping the
IV fluid/blood flow before removing the cassette of the disposable set.
• After applying blood products, clean the hospital administration set using one priming volume of
saline.
• This device may be a potential biohazard during and after use. Handle and dispose in
accordance with acceptable medical practice and applicable regulations.
Other
• Modification of this equipment is not allowed.
2.1.2 Cautions
• Obey local regulations.
• Take care that the device is not dropped, to reduce the risk of damage.
• When (dis)connecting the interface cable, make sure the mains plug is disconnected from the
electrical outlet.
2.1.3 Notes
• Use the Fluido
®
AirGuard System
if a higher flow or a larger volume is requested.
• The device is not intended to control the core temperature of the patient by itself. The device is
intended as a tool to maintain a normothermic core temperature while monitoring the patient’s
core temperature directly by a dedicated sensor inside the patient’s body.
2.1.4 Literature
1.
Reserved operations Blood transfusion, Jacques, M.B., Directorate Education & Training,
2008, Leids Universitair Medisch Centrum; Reader, 2009-04-06.
2.
Guidelines for the use of blood warming devices, AABB, 2002.
3.
Handbook of Transfusion Medicine, DBLL McClelland, UK blood service 4th Edition, ISBN
0-11-322677-2.
4.
Blood and Transplant, NHS, December 2009 version 1.
5.
Fantl and Morris, Thorax (1965),20,372, Influence of dextrose on heparinized blood.