• Do not obstruct the air flow openings or Air Vents of the X5 VAC or place it on a soft surface, such as a bed or couch, where the
air openings or Air Vents may be blocked.
• Keep air openings free of lint, hair, debris or anything that may obstruct air flow. Do not use the X5 VAC or any of the attachments
with any opening blocked.
• Do not handle the X5 VAC, charger, terminals or battery pack with wet hands.
• Do not place the X5 VAC on or near a hot gas or electric burner.
• Do not use the X5 VAC in an enclosed space filled with vapors given off by, for example, oil-based paint, paint thinner or other
explosive or toxic vapors.
• Use extra caution when vacuuming on stairs.
• Keep working area well lit.
• Vacuum fine dirt such as flour or plaster dust only in very small amounts to avoid clogging the unit.
• Before vacuuming highly polished floors, such as sealed hardwood or linoleum, make sure that the underside of the Vacuum Head
is free from foreign objects that could cause marking.
• Before using the X5 VAC or its accessories on flooring, rugs and carpet, consult the flooring manufacturer’s recommended
instructions.
Inspection and Repairs
• Before use, always check for any damage to the Main Unit, the Accessories and the Battery Charger.
• Do not lubricate any parts, or carry out any maintenance or repair work on the X5 VAC or its accessories other than as shown in
this User’s Guide.
After Use and Storing
• It is recommended to empty the Dust Cup and to clean the Mesh Filter and Fabric Filter after each use.
• Store your X5 VAC and accessories indoors in a dry place and away from children.
• When storing after use, ensure the Battery Charger is disconnected from the Battery Pack and unplug from the electrical outlet.
A. IMPORTANT SAFETY INSTRUCTIONS
(continued)
4
27
F. TROUBLE SHOOTING
- LIQUID LIFTER
Solution
• Empty Storage Tank.
• Disconnect Liquid Lifter from Main Body and empty
Storage Tank.
• Disconnect Liquid Lifter from Main Body and empty
Storage Tank. Resume cleaning keeping the Liquid
Lifter in position A or B (see page 19).
• Disconnect Liquid Lifter from Main Body and
thoroughly rinse out entire Liquid Lifter, removing all
dirt and debris that may be stuck inside the unit.
Problem
No lifting or poor lifting of
liquids
Liquid escapes from the
Storage Tank
Possible Cause
• Storage Tank is full
• Storage Tank is full
• Liquid Lifter is being tilted
upside down
• Release Pin is jammed
Table 3. Trouble Shooting