Element Manager Reference
Datacryptor Ethernet User Manual
Page 62
THALES
Configuring SNMP
Datacryptor units record all significant management and error events in their logs for later
examination, but can also be configured to report them immediately to a central location, by
using the SNMP protocol - to help centralize and simplify management. Events are reported as
SNMP Traps V1, v2c, or v3 (as selected on the Traps tab – see below), to a central device
(typically a PC) called an SNMP Network Manager. This SNMP Network Manager must be
compliant with the SNMP agent version support selection on the Agent Configuration tab – see
below. A list of the
log and SNMP trap numbers
with descriptions is provided as an appendix to
this guide.
To configure SNMP, click the
SNMP Config
button on the unit’s
IP Management
tab to display
the
SNMP Config
dialog. This dialog has two tabs – the
Agent Configuration
tab and the
Traps
tab.
Agent Configuration Tab
The
Agent Configuration
tab lists the SNMP communities defined for this unit, and provides
facilities to maintain the list.