Pos. 17
Card recorder (for KPR 2000 Electronic Measuring System)
The card recorder is a separate unit and is connected through a serial cable
to the interface of the KPR 2000. The recorder will be delivered with a
compact-flash-memory card and adaptor with 32 MB of capacity for
recording and downloading information from the cable pulls.
Upon request, every pulling operation can be stored by the KPR 2000
measuring unit in a MS-DOS/Windows compatible file on the memory card.
The corresponding file name for the cable pull will be generated
automatically. Any number of pulling operations can be stored one after the
other due to the large capacity of the memory card.
The data can be evaluated on a PC or Laptop and shown in tabular form. If
the data is required in graphic form, it can be opened in Excel for analysis.
Page 16
Pos. 18 Hydraulic control lever to raise and lower boom
4
Maintenance
These instructions are part of our Warranty Conditions.
Normal wear is not covered by the warranty.
Any customer repairs not authorized by the manufacturer, relieves the
manufacturer of any responsibility for any resulting damage of property or
injury to personnel.
BEFORE MAINTENANCE AND/OR REPAIRS
- When cleaning the machine, avoid directly spraying water or steam on electronic components or
the control panel.
- The work area must be closed to unauthorized personnel.
- Release the hydraulic pressure in the system!
- Properly clean the unit for repair and maintenance.
- Obey the local laws regarding the legal disposal of waste. The following fluids should not reach
the ground or be put into the sewage system during installation, repairs and/or maintenance work.