background image

TH COMMUNICATION SDN BHD     

www.thcomm.com.my

        [email protected] 

Setting

 

Value

 

First field 

Detector name, can be edited 

Room 

Selecting the virtual room to which the device is assigned 

Primary Detector 

If active, the DoorProtect primary detector reacts to opening/closing 

External contact enabled 

If active, the detector registers external detector alarms 

Always active 

If active, the detector always registers opening/closing 

Delay when entering, sec 

Selecting delay time when entering 

Delay when leaving, sec 

Selecting delay time on exit 

Delays in night mode 

Delay turned on when using night mode 

Arm in night mode 

If active, the detector will switch to armed mode when using night 
mode 

Alert with a siren if opening 
detected 

If active, HomeSiren and StreetSiren are activated when the opening 
detected 

Activate the siren if an additional 
contact is open 

If active, HomeSiren and StreetSiren are activated during an external 
detector alarm 

Signal Strength Test 

Switches the detector to the signal strength test mode 

Detection Zone Test 

Switches the detector to the detection area test 

Attenuation Test 

Switches the detector to the signal fade test mode (available in 
detectors with firmware version 3.50 and later) 

User Guide 

Opens the detector User Guide 

Unpair Device 

Disconnects the detector from the Hub and deletes its settings 

Indication 

Event

 

Indication

 

Note

 

Turning on the detector 

Lights up green for about one 
second 

 

Detector connection to the 
Hub, ocBridge, and 
uartBridge 

Lights up continuously for a 
few seconds 

 

Alarm / tamper activation 

Lights up green for about one 
second 

Alarm is sent once in 5 seconds 

Содержание DoorProtect

Страница 1: ...f ferromagnetic contacts placed in a bulb DoorProtect operates within the Ajax security system by connecting via the protected Jeweller protocol to the Hub Communication range up to 1 200 m absent any obstacles In addition the detector can be used as part of third party security central units due to the uartBridge or ocBridge Plus integration module The detector is set up via a mobile application ...

Страница 2: ...The detector is attached to a frame and the magnet to a moving wing or sliding part If the sealed contact reed relay is within the coverage area of the magnetic field it closes the circuit the detector is closed The opening of the wing distances the magnet from the sealed contact reed relay resulting in the circuit opening and the detector records opening A small magnet acts at a distance of 1 cm ...

Страница 3: ...e Hub and check the internet connection via Ethernet cable and or GSM network Ensure that the Hub is disarmed and does not start updates by checking its status in the mobile application Only users with administrative privileges can add the device to the hub How to connect the detector to the Hub 1 Select the Add Device option in the Ajax application 2 Name the device scan write manually the QR Cod...

Страница 4: ...ub failed switch off the detector for 5 seconds and repeat the attempt The detector connected to the hub will appear in the list of devices of the hub in the application Update of the detector statuses in the list depends on the device inquiry time set in the hub settings with the default value 36 seconds Connecting the Detector to Third Party Security Systems To connect the detector to a third pa...

Страница 5: ...measured on the processor and changes gradually Signal Strength Signal strength between the hub and the detector Battery Charge Battery level of the detector displayed in increments of 25 Lid The tamper mode of the detector which reacts to the detachment of or damage to the body Delay when entering sec Delay time when entering ...

Страница 6: ...n status between the hub and the detector Primary Detector Primary detector status Secondary detector Status of the external detector connected to DoorProtect Always active If active the detector is always in the armed mode Firmware Detector firmware version Device ID Device identifier Setting Up the Detector Devices DoorProtect ...

Страница 7: ...opening detected If active HomeSiren and StreetSiren are activated when the opening detected Activate the siren if an additional contact is open If active HomeSiren and StreetSiren are activated during an external detector alarm Signal Strength Test Switches the detector to the signal strength test mode Detection Zone Test Switches the detector to the detection area test Attenuation Test Switches ...

Страница 8: ...ring the radio signal transmission walls inserted floors large size objects located within the room Check the signal level at the installation location If the signal level is one division we cannot guarantee stable operation of the security system Take possible measures to improve the quality of the signal As a minimum move the device even 20 cm shift can significantly improve the quality of recep...

Страница 9: ...t they do not damage or deform the panel The double sided adhesive tape may be only used for temporary attachment of the detector and magnet The tape will run dry in course of time which may result in falling of DoorProtect and actuation of the security system Furthermore the device may fail from a hit 2 Put the detector on the attachment panel As soon as the detector is fixed in SmartBracket it w...

Страница 10: ...arby any metal objects or mirrors causing attenuation and screening of the signal within any premises with the temperature and humidity beyond the range of permissible limits Connecting a Wire Detector A wire detector with an NC type contact may be connected to the DoorProtect using an outside mounted terminal clamp We recommend to install the wire detector at a distance not exceeding 1 meter incr...

Страница 11: ...nts The service life of the detector from the battery depends on battery quality the actuation frequency of the detector and inquiry interval of the detectors by the Hub If the door opens 10 times a day and the detector inquiry interval is set at 60 seconds then DoorProtect will operate 7 years from the pre installed battery You will reduce the service life of the device to 2 years by setting the ...

Страница 12: ...ating temperature range From 10 С to 40 С Operating humidity Up to 75 Dimensions Ø 20 х 90 mm Weight 29 g Complete Set 1 DoorProtect 2 Battery CR123A pre installed 3 Big magnet 4 Small magnet 5 Outside mounted terminal clamp 6 Installation kit 7 Quick Start Guide Warranty Warranty for the AJAX SYSTEMS MANUFACTURING LIMITED LIABILITY COMPANY products is valid for 2 years after the purchase and does...