If the external detector is actuated, you will receive the notification.
Detector Maintenance and Battery Replacement
Check the operational capability of the DoorProtect detector on a regular basis.
Clean the detector body from dust, spider web and other contaminations as they appear. Use
soft dry napkin suitable for equipment maintenance.
Do not use for cleaning the detector any substances containing alcohol, acetone, gasoline and
other active solvents.
The service life of the detector from the battery depends on battery quality, the actuation
frequency of the detector and inquiry interval of the detectors by the Hub.
If the door opens 10 times a day and the detector inquiry interval is set at 60 seconds, then
DoorProtect will operate 7 years from the pre-installed battery. You will reduce the service life of
the device to 2 years by setting the inquiry interval at 12 seconds.
If the detector battery is discharged, the user will receive a notice, and the LED will smoothly
light up and go out if the detector or tamper is actuated.
Tech specs
Sensor
Sealed contact reed relay
Detector actuation threshold
1 cm (small magnet)
2 cm (big magnet)