Service manual
- 39 -
9.11 Two speeds outdoor fan function
9.11.1 Outdoor fan starts at the same time with compressor, but stops 30 seconds later after compressor stop.
9.11.2 Outdoor fan action in heating mode(including heating in auto mode).
9.11.3 Outdoor fan action in cooling & drying mode(including cooling in auto & forced mode).
Please refer to the pic. above.
9.12 Timer function
9.12.1 Timing range is 24 hours, and the minimum resolution is 15 minutes.
9.12.2 Timer on. After turning off, the machine will turn on automatically when reaching the setting time.
9.12.3 Timer off. After turning on, the machine will turn off automatically when reaching the setting time.
9.12.4 Timer on/off. After turning off, the machine will turn on automatically when reaching the setting “on” time, and then
turn off automatically when reaching the setting “off” time.
9.12.5 Timer off/on. After turning on, the machine will turn off automatically when reaching the setting “off” time, and then
turn on automatically when reaching the setting “on” time.
9.12.6 The tolerance of Timer is 1 minute per hour.
9.13 Sleep function mode
9.13.1 Operation time in sleep mode is 7 hours. After 7 hours the machine quits this mode and turns off.
9.13.2 In cooling, heating or auto mode sleep function is available.
9.13.3 Operation process in sleep mode is as follow:
After pressing ECONOMIC or SLEEP button on controller, the machine will turn into sleep mode.
When cooling, the setting temperature rises 1
℃
(be lower than 30
℃
) every one hour, 2 hour later the rising stops and
indoor fan is fixed as low speed.
When heating, the setting temperature descends 1
℃
(be lower than 30
℃
) every one hour, 2 hour later the descending
stops and indoor fan is fixed as low speed, and anti-cold-wind is available.
9.13.4 If user uses timer on function in sleep mode, sleep function will pause and not resume until reaches the setting on
time.
9.13.5 When user uses timer off function in sleep mode(or sleep function in timer off mode), if the timing time is less than 7
hours, sleep function will be cancelled when reaching the setting time. If the timing time is more than 7 hours, the machine will
not stop until reaches the setting off time in sleep mode.
Outdoor fan action in cooling & drying
mode
17
15
out
door
low
high
out
door f
an s
p
e
ed
Outdoor fan action in heating mode
(including heating in auto mode).
22
20
out
door
high
low
out
do
or f
an sp
ee
d
Содержание MWVT09S
Страница 1: ......
Страница 17: ...Service manual 16 5 Refrigerant cycle diagram Cooling only mode Heat pump mode ...
Страница 19: ...Service manual 18 MRVT09AS MRVT12AS Outdoor unit ...
Страница 20: ...Service manual 19 MRHVT09AS MRHVT12AS Outdoor unit ...
Страница 21: ...Service manual 20 MRVT18AS MRHVT18AS Outdoor unit ...
Страница 22: ...Service manual 21 MWVT24S MWHVT24S Indoor unit ...
Страница 23: ...Service manual 22 MRVT24AS Outdoor unit ...
Страница 24: ...Service manual 23 MRHVT24AS Outdoor unit ...