Service manual
- 34 -
I1COOL I2COOL I3COOL
9K Model
5.0 A
6.5 A
7.5 A
12K Model
5.5A
7.0 A
7.8 A
18K Model
9.5 A
10.5 A
13A
24K Model
11 A
12A
13 A
9.5.4 Rating capacity test function
1) Set the indoor unit with remote controller as: high fan, 17
℃
in cooling mode, then press “TURBO” button on controller 6
times or more within 10 seconds(make sure indoor unit receives these signals), the machine will turn into rating capacity test
mode, the buzzer will make a “di” sound for 2 seconds continuously. Also, indoor fan will change to rating speed, the frequency
of compressor will be fixed as rating value. Any condition of above is not satisfied, the machine can not be turned into rating
capacity test mode.
2) The machine will quit from the rating capacity test mode if running for 5 hours or changing fan speed or setting
temperature.
9.5.5 Turbo function(press the “TURBO” button on remote controller)
Elevate current frequency to a higher grade.
Indoor fan turns to turbo speed.
After running for 30 minutes the machine will turn back to previous setting mode.
9.6.6 Indoor fan operation rule.
In cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and auto.
Auto fan in cooling mode acts as follow:
9.5.7 Condenser high temperature protection function(in cooling and drying mode)
If T
3>
60
℃
for 5 seconds, compressor will stop immediately, and the machine will not resume until T
3<
52
℃
.
9.6 Drying mode
9.6.1 Indoor fan speed is fixed at breeze grade and can’t be changed. The horizontal angle is the same as in cooling
mode.
9.6.2 Room overlow temperature protection
In drying mode, if room temperature is lower than 10
℃
, compressor will stop and not resume until room temperature climbs
up to 12
℃
.
9.6.3 Evaporator anti-freezing protection, condenser high temperature protection and outdoor unit frequency limit are valid,
and they are the same as that in cooling mode.
9.6.4 Horizontal louver action is the same as that in cooling mode.
∆
T=
(room
t
e
m
p
) – (set
ting
Te
m
p)
medium
4.0
3.0
1.5
1.0
high
low
Содержание MWVT09S
Страница 1: ......
Страница 17: ...Service manual 16 5 Refrigerant cycle diagram Cooling only mode Heat pump mode ...
Страница 19: ...Service manual 18 MRVT09AS MRVT12AS Outdoor unit ...
Страница 20: ...Service manual 19 MRHVT09AS MRHVT12AS Outdoor unit ...
Страница 21: ...Service manual 20 MRVT18AS MRHVT18AS Outdoor unit ...
Страница 22: ...Service manual 21 MWVT24S MWHVT24S Indoor unit ...
Страница 23: ...Service manual 22 MRVT24AS Outdoor unit ...
Страница 24: ...Service manual 23 MRHVT24AS Outdoor unit ...