MANUAL P/N 900000165 REV H
50
codenumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..14))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Firmware part number"
::= {common 4}
codeversion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Firmware version number"
::= {common 5}
systemstatus OBJECT IDENTIFIER ::= {tfs 4}
lastevent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Last event ID"
::= {systemstatus 2}
syslogTable OBJECT-TYPE
SYNTAX SEQUENCE OF SyslogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "System log table"
::= {systemstatus 1}
syslogEntry OBJECT-TYPE
SYNTAX SyslogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "System log record"
INDEX {eventid}
::= {syslogTable 1}
SyslogEntry ::= SEQUENCE { timestamp INTEGER,
resolver INTEGER,
eventid INTEGER,
severity INTEGER,
module OCTET STRING,
function OCTET STRING,
description OCTET STRING
}
timestamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "time as number of secs since 1 January 1970"
::={syslogEntry 1}
resolver OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "fractions of seconds as a count of 15.25ns pulses"
::={syslogEntry 2}
eventid OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION "Event log index"
::={syslogEntry 3}
severity OBJECT-TYPE
Содержание NTP80plus