MANUAL P/N 900000165 REV H
46
12
Appendix A
12.1
Resetting Factory Defaults.
Connect a terminal to the serial port, with serial parameters 115200 baud, 8 bits/char, no parity
and 1 stop bit.
Power up the NTP80, the following menu will appear:
1>
Firmware Update
2>
Factory Def.
As soon as this menu appears press 1 to reset the NTP80 back to the following factory defaults.
If the operation was successful the unit responds:
Restore to factory defaults set.
After the unit has initialised the settings will be as follows:
Network ports:
ETH1
192.168.101.10/255.255.255.0
ETH2
192.168.102.10/255.255.255.0
ETH3
192.168.103.10/255.255.255.0
No gateways are set.
HTTP pages
Username:
admin
Password:
ThePassword.
There will be no network restrictions.