15
2011
Tracing the Path of a Hidden Wire (Live Circuit)
Electric shock hazard:
Contact with live circuits can result in severe injury or death. Use
only the plug and adapters provided with the 2011 when tracing
circuits.
Failure to observe this warning will result in severe injury or death.
Electric shock hazard:
Do not connect to voltage greater than 600 V AC/DC. Check circuit voltage before
•
plugging in transmitter.
Connect ground or neutral first when using clip leads or adapters. Current flows
•
through both the hot and ground or neutral transmitter lead.
Failure to observe these warnings could result in severe injury or death.
Follow steps 1 through 3, using separate or earth ground, under “Locating a Circuit
Breaker (Live Circuit),” to set up the transmitter. Then:
4. Beginning at transmitter, scan the area with a sweeping motion parallel to the wall until
you locate the signal. The signal will indicate the wire path.
In HIGH RANGE the receiver will indicate you are within tracing distance by initially
flashing all five LEDs. It will then automatically turn the signal level down to three
LEDs. If the signal is lost, push the HIGH RANGE button again and return to where you
last picked up the signal. This will reset the signal level at three lights. The signal level
will automatically turn down as you get closer to the signal wire. This creates the most
accurate reading possible, based on the receiver’s distance from the signal wire.