39
6-5-3. Storing values in preset memory in MAIN OUTPUT key on mode
Operation procedures
1. Press the LIMIT key while the MAIN OUTPUT key is on.
2. Set voltage and current are displayed on the voltage and current indicators.
3. Press the PRESET key of the preset memory whose data should be changed. The LED of some
PRESET key (1 to 4) is lit. Note that no data may be written in the preset memory whose LED is lit.
4. The LED of the PRESET key pressed in step 3 blinks. The voltage and current stored in that
preset memory are displayed.
5. Change the displayed voltage and current to intended values.
6. Press the PRESET key whose LED is blinking.
The LED goes out and the voltage and current set
in step 5 are written in that preset memory. (To cancel the memory operation, press the MEMORY key
without pressing the PRESET key whose LED is blinking.) On completion of operation, the set voltage
and current are displayed on the voltage and current indicators. (Condition in step 2)
6-5-4. Copying preset values
Operation procedures
1. Press the PRESET key of the memory where the original voltage and current are stored.
The LED of the key is lit up in green.
2. Press the MEMORY key. The LED of the PRESET key pressed in step 1 blinks in green.
3. Press the PRESET key of the memory where the data should be copied. The LED of the PRESET
key blinking in green goes out, and the LED of the pressed PRESET key is lit up in green.
The set voltage and current are copied in the preset memory whose LED is lit in green.
6-5-5. Storing setting of each key
Function: It is possible to store the settings of the OUTPUT SELECT, DISPLAY/STATUS, PRESET,
TRACKING ON/OFF and TRACKING abs( )/% DELAY ON/OFF keys when the power
switch is thrown.
Operation procedures
・
Press the MEMORY key when the MAIN OUTPUT key is off. Then, press the DISPLAY/STATUS
key whose LED is lit in orange. All DISPLAY/STATUS keys are lit up in orange instantaneously.
The key settings will be stored when the power switch is thrown.
・
To cancel operation, press the MEMORY key, instead of the DISPLAY/STATUS key, in the same
procedures.
6-5-6. Initializing setting
Function: This function initializes the settings of the PRESET 1 to PRESET 4 keys, delay time, and
tracking function (to the default settings)
Operation procedures
・
Throw the power switch while holding the MEMORY key. The characters "dAtA" and "ClAr" are
displayed on the current indicator and voltage indicator, respectively, and the memory is initialized.
・
It takes about 30 seconds (approx 2 seconds for after Ver. 3.00 of the unit) to initialize the data.
(All other functions of the PW-A power supply unit are deactivated.)
<Precautions>
・
Do not shut off the power switch for the initialization period. Results of initialization are not guaranteed
if the power switch is shut off. Retry initialization of it fails.
Содержание PW16-2ATP
Страница 2: ......
Страница 85: ...75 11 OUTSIDE DIMENSIONS V sec A 18 4 380 4 5 137 1 5 1 5 8 5 124 15 4 138...
Страница 86: ...1850 1 Tsuruma Machida shi Tokyo 194 0004 Japan http www texio jp...