INS467-9 23/47

the “Setup Users” Menu.

Ricochet and Premier Elite Series V2.xx firmware upgrades add additional
capabilities to the management of Premier Elite SmartKey™. In multiple
expander systems it is now possible to choose which zones (and therefore
expander) the Premier Elite SmartKey™ will use for its routing, LED and Aux
functions can also be changed within the “Setup Users” menu.

All users on the system can have a Premier Elite SmartKey™ a TAG and a code,
or any combination of them.

This section only deals with Premier Elite SmartKey™ learning and routing, all
other user programmable options can be found in INS176-8 or later Premier Elite
Series Installation Manual
.

N

 

Great care should be taken when using large numbers of Premier Elite

SmartKey™, only one Premier Elite SmartKey™ per expander can be used by
the system at any one time, and on Multiple expanders systems, or large sites,
functionality should be checked in all areas of the site where the device may be
used.

Premier Elite SmartKey™ Routing

Premier Elite SmartKey™ should only be learned to the system AFTER all
devices have been learned and placed in their final location. Whilst it is possible to
learn at any point during the programming of the system, learning and testing the
functionality of the Premier Elite SmartKey™ after all devices have been placed
will ensure that the Premier Elite SmartKey™ performs as expected, and works
in locations where the user would expect it too.

Route By

The Route By function allows you to select which Zones (and therefore expander)
the Premier Elite SmartKey™ will use on the system for its routing. This should
be selected BEFORE the device has been learned.

In the examples below Fig 1 shows the zones associated with Expander 1, which is
a 32XP-W, and Fig 2 shows Expander 2 which is also a 32XP-W, when using 8XP-W

Содержание Premier Elite 8XP

Страница 1: ...Premier Elite 8XP W 32XP W Wireless Mesh Networking Expander INS467 9...

Страница 2: ...Ricochet V2 xx 19 5 6 Premier Elite SmartKey 22 5 7 Premier 412 816 V9 5 V11 10 Later Premier 832 2 5 V4 10 Later 26 5 8 Learning Devices directly to the 8XP W 32XP W 30 5 9 Using the Engineers Keypa...

Страница 3: ...e locations in a building Each Ricochet enabled device provides signalling routes to and from control panels If the wireless communication between devices weakens the Ricochet network self heals and a...

Страница 4: ...w features and functions for Ricochet enabled security systems N DO NOT mix V1 V2 V3 expanders on the same Premier Elite panel V3 Expander Diagnostics V3 expanders have the ability to display diagnost...

Страница 5: ...for greater exibility in system design and also taking wireless capability to new levels Control Panel Capacity The table below details the maximum number of expanders devices and Premier Elite Smart...

Страница 6: ...n using multiple expanders great care should be taken when designing the system Each expander should be treated as its own wireless network it is not possible for devices to hop from one wireless netw...

Страница 7: ...ed are those furthest away from the expander Make sure to install devices with the expander in Commission mode See chapter 7 1 Devices also have a commission mode which will indicate a secure and vali...

Страница 8: ...INS467 9 8 47 3 0 Quick Start Guide...

Страница 9: ...nterface lead can be temporarily plugged onto this connector to allow system programming and testing Functions dependent on Panel rmware version Set the keypad address switches to all on 2 Network Con...

Страница 10: ...please see chapter 6 0 7 Antenna RF Antenna 8 Network LED s Green LED Data received by the expander from the panel Red LED Data transmitted by the expander to the panel The ash rate depends on the mo...

Страница 11: ...d 16 Flash Programming Port Variant dependent for ashing the expander with updated rmware 4 1 Mounting the Expander Remove each screw cap by inserting a at bladed screwdriver into the slot and turning...

Страница 12: ...lows The networks are made up of four terminals incorporating power and data To ensure correct operation all four terminals on the device must be connected to the corresponding terminals on the contro...

Страница 13: ...on will depend on which combination of expanders are being used Each 32XP W takes up 4 address slots on the control panel network however the network slots are virtual until devices are assigned to av...

Страница 14: ...Control panels please contact Technical Support to obtain a legacy manual It is highly recommended that you upgrade the Panel Firmware to the latest version to ensure full compatibility however the sy...

Страница 15: ...in the User Menu as described later in this section Learn Devices from rst power up Follow the instructions given in INS176 8 or later for the rst power up of the system When the Con rm Devices menu a...

Страница 16: ...B Okey will take you to the Ricochet learn menu above IMPORTANT In all cases when entering the Learn menu the next available free Zone will be chosen to learn a device too It will not be possible to l...

Страница 17: ...d zones these will be switched to Not Used after the rst Ricochet device is learned to the system the following defaults will be used for Ricochet devices learned to the system IMPORTANT If any editin...

Страница 18: ...icochet Diagnostics Scroll to the rst wireless zone for the expander being defaulted and press followed by All zones will be deleted If all devices are deleted from the system the following will be sh...

Страница 19: ...e User Setup menu the Con gure Radio menu in Engineer s Utilities is now redundant and should only be used for Legacy systems Learning Devices To learn a device to a Zone select the Zone from the Zone...

Страница 20: ...shows Learning press R R N To default the expander completely put option switch 1 2 to ON and hold the white programming button until the expander programming LED s all illuminate and turn o Device M...

Страница 21: ...the relevant devices N Premier Elite DT W should ALWAYS be used in Hybrid mode failure to do this will have an adverse a ect on battery life Device Speci c Mode Device Speci c mode is used to control...

Страница 22: ...ease refer to INS176 Zone setup for the details when using the X and NO key to change these settings 5 6 Premier Elite SmartKey Introduction Premier Elite SmartKey are now learnt and all functionality...

Страница 23: ...by the system at any one time and on Multiple expanders systems or large sites functionality should be checked in all areas of the site where the device may be used Premier Elite SmartKey Routing Pre...

Страница 24: ...ch zones are being used for routing It is not possible to alter this once learned To change the routing the Premier Elite SmartKey should be deleted and the process started from the beginning Deleting...

Страница 25: ...Con g options 38 48 N Once the 16 slots on a XP W are taken up the learn process will fail and display No spaces left N In either of the Premier Elite SmartKey menu displays any Premier Elite SmartKe...

Страница 26: ...device slot taken on the expander This should always be started at 01 If started at 05 for example the next devices will go to 06 and you may run out of device slots N For V16 panels all Ricochet devi...

Страница 27: ...the selected zone Program the zone type and attributes as required Note The Zone Wiring 5 must be programmed as Double EOL if a tamper response is required from the detector Repeat steps 2 5 for othe...

Страница 28: ...one Learning SmartKey All SmartKey must be assigned to one of the available users on the system SmartKey will always be learned to the last available slot on the receiver and work downwards The users...

Страница 29: ...normal 6 way SmartKey If a SmartKey is no longer required it must be unassigned from the system To remove a SmartKey from a user proceed as follows Select engineer s mode by entering the engineer cod...

Страница 30: ...able to legacy systems For all Legacy Control panels please contact Technical Support to obtain a legacy manual 6 0 Ricochet Diagnostics 6 1 Premier Elite 8XP W 32XP W V3 XX Diagnostic information is...

Страница 31: ...lite SmartKey and Ricochet devices via Zones and Users Devices For Devices the following information can be viewed Routing RSSI Alarms and Status Device visibility Time since last message N The C Ckey...

Страница 32: ...n as at each of the hops If question marks appear on the display it means the information is not available N If question marks appear it could be because either the system has just been powered up and...

Страница 33: ...INS467 9 33 47 Example N On the 32XP W there are 16 windows to show information from the 32 devices of the system the format is the same Device Status...

Страница 34: ...INS467 9 34 47 Premier Elite SmartKey Messages...

Страница 35: ...INS467 9 35 47 N This option DOES NOT remove known Premier Elite SmartKey use the Delete option in Setup Users Ricochet Diagnostics Menu...

Страница 36: ...tem is updated live and therefore it is possible to determine changes by moving devices or by adding more to the system The information displayed replicates what is seen when using Ricochet Monitor Lo...

Страница 37: ...ate the LED for a short period of time whilst communication with the receiver is established The LED will ash indicating the device is trying to communicate with the receiver once communication is suc...

Страница 38: ...gger 24 hour circuits or where the zone is required to chime ensure the device attributes are at the default Always Awake as detailed in chapter 8 2 The two additional inputs may also be used to trans...

Страница 39: ...Please see chapter 7 1 for details The standard poll time is not adjustable If the system is powered down for more than 1 hour the devices will go into an O ine Mode to conserve battery life in this c...

Страница 40: ...d Mode V2 xx Hybrid mode is used to control the reporting functions for devices When in this mode devices are asleep when the system is unset and are woken up by the control panel at the point of armi...

Страница 41: ...l communication with the system 2 Flashing Blue communication with system 3 Red Out of Range 4 Turquoise Function Mode 5 N on Premier 412 816 832 Function 1 is the Arm Button and Function 2 is the Dis...

Страница 42: ...e enabled the outputs should be programmed in the control panel to activate the desired function Please refer to the Control Panel manual for details on how to programme the outputs N The Function Key...

Страница 43: ...ey will arm all three areas N Great care should be taken if the user is assigned to more than one area or subsystem It is not possible for the user to determine from the SmartKey which areas are ARMED...

Страница 44: ...vices Please see the device instructions for details of the correct battery required 8 5 Premier Elite 8XP W 32XP W Power Loss If the power to the receiver is lost for more than one hour all devices o...

Страница 45: ...se the latest version available from our website 9 0 Speci cations 9 1 Electrical Operating Voltage 10 13 7VDC Current Consumption 120mA Network 4 wire standard 7 0 2 alarm cable up to 250m Star Daisy...

Страница 46: ...s marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new eq...

Страница 47: ...testing As a result the Premier 8XP W 32XP W expander is covered by a two year warranty against defects in material or workmanship As the Premier Elite 8 XP W 32XP W expander is not a complete alarm...

Отзывы: