Texecom Premier Elite 32XP-W Скачать руководство пользователя страница 3

Premier Elite 8XP-W & 32XP-W Installation Manual 

INS467-8 

2.

 

Premier Elite 8XP-W & 32XP-W 

Texecom  has  developed  a  new  method  of  wireless  security  signalling  based  on  the  concept  of  mesh 

networking. Mesh-networking is the process whereby every single wireless device is capable of receiving 

and retransmitting any signal from any other wireless device on the network. The size, scalability and range 

of  the  entire  system  are  extended  as  wireless  signalling  is  no  longer  limited  by  point-to  point 

communications. The range of a 

Ricochet

®

 enabled wireless system is greater than previous systems, with 

multiple devices capable of relaying messages to and from even the most remote locations in a building. 

Each 

Ricochet

  enabled  device  provides  signalling  routes  to  and  from  control  panels.  If  the  wireless 

communication  between  devices  weakens,  the 

Ricochet

 

network  ‘self

-

heals’  and  automatically

  re-routes 

communications via alternate 

Ricochet

 enabled devices. The reliability of the wireless system increases as 

more 

Ricochet

 devices are installed. 

SignalSecurity

™ further enhances network reliability with each device 

already aware of the number of communication paths available to it. 
The 

8XP-W 

&

 32XP-W

 expanders can be used on any premier control panel; however certain features and 

functions are dependent on the version of panel firmware as detailed in the table below. To determine the 
firmware version of your control panel press 

/

 4 on the keypad. 

 

Firmware versions prior to those listed are 

NOT

 compatible. 

Control Panel 

Premier 8 XP-W & 

32XP-W 

Legacy 

Ricochet 

Ricochet V2/V3.xx 

Premier 412 

V10.5 

 V11.07 

V11.10> & PV1.0> 

Ricochet Mode 

Premier 816 

V10.5 

 V11.07 

V11.10> & PV1.0> 

Ricochet Mode 

Premier 816E 

Not supported 

Premier 832 

V3.5 

 V4.07 

V4.10> & PV1.0> 

Ricochet Mode 

Premier 24 

V7.00 

 V8.23 

V8.24> 

Ricochet Mode 

Premier 48/88/168 

V7.00 

 V8.13 

V8.15> 

Ricochet Mode 

Premier 640 

V7.00 

 V8.15 

Not Released 

Ricochet Mode 

V1 Premier Elite 

24/48/88/168 & 640 

N/A 

V1.00> 

Ricochet Mode 

V2-V2.09 Premier 

Elite 24/48/88/168 & 

640 

See Section 3 

N/A 

V2.00> 

V2.00> 

** V2.10 > Premier 

Elite 

12/24/48/88/168 & 

640* 

See Section 3 

N/A 

V2.10> 

V2.10> 

V4.00 > Premier 

Elite 

12/24/48/88/168 & 

640* 

See Section 3 

N/A 

V3.00> 

V3.00> 

** New dedicated 

Ricochet

 

learn menu added. Existing methods of learning still exist. 

 

Содержание Premier Elite 32XP-W

Страница 1: ...Installation Manual Premier Elite 8XP W Premier Elite 32XP W INS467 8...

Страница 2: ...Key 16 Premier 412 816 V9 5 V11 10 Later Premier 832 2 5 V4 10 Later 17 Option Switch Settings 17 Expander Settings 17 Removing Detectors 18 Learning SmartKey 18 SmartKey 19 Learning Devices directly...

Страница 3: ...stalled SignalSecurity further enhances network reliability with each device already aware of the number of communication paths available to it The 8XP W 32XP W expanders can be used on any premier co...

Страница 4: ...88 168 640 to V4 X X Relearn if you Flash Elite 12 W 24 W 48 W to V4 X X V2 X X V3 X X All Versions Yes No No V4 X X 1 X X 2 X X Yes No No 3 0 6 No No No V3 Multiple Expander Support V2 introduced mul...

Страница 5: ...that they are registered on the receiver or control panel and that Mesh Networks and routing are established correctly Please refer to the relevant section in this document to Learn Devices to the sy...

Страница 6: ...Legacy Contact Technical Support for a Legacy Manual Ensure all Option Switches are off See Page 7 Learn Devices to Control Panel See Page 10 Onwards set attributes See Page 10 Onwards Place Devices...

Страница 7: ...tions Switch Use to select the receiver functionality depending on panel firmware Switch 1 ON firmware dependant please see the relevant programming section Switch 2 ON Legacy Mode OFF Ricochet Switch...

Страница 8: ...an be used for most installations However under certain conditions it may be necessary to use screened cable Selecting an Address Each expander must be assigned a different address using the DIL switc...

Страница 9: ...N A N A N A N A N A N A N A N A N A N A N A N A N A N A Premier Elite 168 Exp 1 Exp 2 Exp 1 Exp 2 N A N A N A N A N A N A N A N A N A N A N A N A Expander Address 1 5 1 5 N A N A N A N A N A N A N A N...

Страница 10: ...ed Ricochet learn menu accessible via the key when in Engineer menu This new feature is only for devices SmartKey should be learnt to the system in the User Menu as described later in this section Lea...

Страница 11: ...pe Area When learning devices if no editing has taken place of the control panel onboard hardwired zones these will be switched to Not Used after the first Ricochet device is learned to the system the...

Страница 12: ...se this key to exit the Learn Menu Premier EliteV2 00 V2 09 24 48 88 168 640 Ricochet V2 xx Option Switches All Off Introduction V2 xx firmware added the option to learn Ricochet devices through the Z...

Страница 13: ...is the default mode for all single technology motion detectors Hybrid Mode Hybrid mode is used to control the reporting functions for devices When in this mode devices are awake only when the system...

Страница 14: ...n Learning 20s Zone 00 Learn P R P 0 0 y Zone 00 P0 0 Not sed n n y Zone 00 Attrib y Zone 00 Attrib2 A Zone 00 Areas A y Zone 00 Text n n y Zone 00 Chime Silent n n y Zone 00 Test Remote Test Off n n...

Страница 15: ...on Whilst it is possible to learn at any point during the programming of the system learning and testing the functionality of the Premier Elite SmartKey after all devices have been placed will ensure...

Страница 16: ...A Please refer to page 27 for details of the LED AUX funtions To disable two stage arming please refer to INS176 8 or later and check Global Options System Config options 38 48 Once the 16 slots on a...

Страница 17: ...r s mode by entering the engineer code followed by then 2 Enter to select the Assign Radio Device menu if an error tone is generated then the receiver is not installed or configured correctly 3 Enter...

Страница 18: ...e receiver and work downwards The users available will vary depending on the control panel Control Panel Available Users Premier 412 Users 1 to 31 Premier 816 Users 1 to 31 Premier 832 Users 1 to 63 S...

Страница 19: ...he SmartKey from e g 4 Press the key the panel will generate an acceptance tone and the SmartKey is no longer assigned to the selected user Note If the SmartKey was assigned to user 02 onwards the use...

Страница 20: ...ter Engineer Utilities now includes a new Ricochet Diagnostics menu This menu displays information about the live system and is split into Premier Elite SmartKey and Ricochet devices via Zones and Use...

Страница 21: ...ion from the device was over an hour ago Zone 00 P R No msg recvd yet This display shows that no message has been received yet this would normally be seen on a recently powered up system wait 15 minut...

Страница 22: ...ed onto the system ser002 Ricochet Partarm Bat OK Shows the different messages displayed when the relevant buttons are pressed ser002 Ricochet Disarm Bat OK ser002 Ricochet ullarm Bat OK ser002 Ricoch...

Страница 23: ...Zone 00 Shock Status aaaSpdtt Zone 00 Shock P Zone 00 Shock P C Zone 00 Not Ricochet C B ser000 Ricochet Not Ricochet U ser002 Ricochet Not connected Zone 00 Shock C Zone 00 Shock hr since msg C C se...

Страница 24: ...nabled when the expander is in tamper When in commission mode the RF signal is attenuated by 6 dB and will reject weak signals This means that when devices are placed into their final locations and co...

Страница 25: ...being used to trigger 24 hour circuits or where the zone is required to chime ensure the device attributes are at the default Always Awake as detailed on page 26 The two additional inputs may also be...

Страница 26: ...W and Impaq Plus W For example a Impaq Contac W on a door which you need to know is opened regardless of system state or devices such as PA buttons smoke detectors which have been connected to the in...

Страница 27: ...xiliary devices from the control panel outputs The function keys should first be enabled either from the Engineers Keypad or Ricochet Monitor Once enabled the user can enter Auxiliary mode by pressing...

Страница 28: ...ee alarm status LED s will flash to indicate an arm failure In the case of users assigned to multiple areas the whole system should be unset and each area investigated to determine the cause of the ar...

Страница 29: ...g Voltage 10 13 7VDC Current Consumption 120mA Network 4 wire standard 7 0 2 alarm cable up to 250m Star Daisy Chain or any combination Outputs 1 8 Not Used Operating Temperature 10 C 14 F to 50 C 122...

Страница 30: ...II Hereby Texecom declares that the radio equipment type GCA1000 2 and GCD1000 2 Premier Elite 32XP W and Premier Elite 8XP W is in compliance with Directive 2014 53 EU The full EU declaration of conf...

Страница 31: ...Premier Elite 8XP W 32XP W Installation Manual INS467 8 31 Notes...

Страница 32: ...Lancashire BB4 4PW England Technical Support UK Customers Tel 08456 300 600 Calls charged at local rate from a BT landline Calls from other networks may vary International Customers Tel 44 1706 233875...

Отзывы: