Texecom Premier Elite 32XP-W Скачать руководство пользователя страница 28

Premier Elite 8XP-W & 32XP-W Installation Manual 

28 

INS467-8 

For  example  in  a  two  area  system  where  one  area  is  ARMED  and  one  is  DISARMED,  both  the  ARMED  & 

DISARMED 

LED’s will be on. If the user then presses the 

DISARM button, the area which is currently ARMED 

will be DISARMED, and vice versa. 
If the user has control over three areas and only the DISARMED LED is illuminated, it means that all areas the 

user is assigned too are DISARMED, pressing the ARM key will arm all three areas. 

 

Great care should be taken if the user is assigned to more than one area or subsystem. It is not possible for the 

user to determine from the 

SmartKey™

 which areas are ARMED and which are DISARMED. It is important that in 

these  situations  the  user  has  access  to  an  alternative  means  of  setting  and  unsetting  the  system  so  that  the 

possibility of false alarms from the system are minimised. 

 

(hold 4 secs)

POWER

ARM

DISARM

PART ARM

Alarm status LED’s

SmartKey status LED

DISARMED

PART ARMED

ARMED

 

Arm Fail Indication 

If the system or any area assigned to a user fails to arm, all three 

alarm  status  LED’s  will  flash  to  indicate  an  arm  failure.  In  the 

case  of  users  assigned  to  multiple  areas  the  whole  system 

should  be  unset  and  each  area  investigated  to  determine  the 

cause of the arm failure. 

 

Battery Considerations 

Battery life for all devices will be determined by system complexity, the number of devices that hop, and the 

use of the Always Awake mode. 
In a typical system, battery life should be up to 4 years for devices, hopping devices should achieve between 

2-3 years. 
Always Awake. Mode should 

NOT

 be used for devices which are subject to multiple activations. 

Batteries should only be replaced with an equivalent of those supplied with the devices. Please see the device 

instructions for details of the correct battery required. 

SmartKey™

 

The 

SmartKey™

 battery should last 2-3 years in normal use.

 

SmartKey™

 batteries are 

NOT

 replaceable; in the case of a

 

SmartKey™

 battery failing the device should be 

replaced. Please contact your distributor to arrange a replacement. 

Low Battery 

Warning 

All devices, including 

SmartKey

 will transmit a Low Battery Warning when there are 

three months remaining. 

Battery 

Maintenance 

The system should be checked for low battery warnings at each service interval or a 

minimum of 12 months whichever is sooner. 

 
 

Содержание Premier Elite 32XP-W

Страница 1: ...Installation Manual Premier Elite 8XP W Premier Elite 32XP W INS467 8...

Страница 2: ...Key 16 Premier 412 816 V9 5 V11 10 Later Premier 832 2 5 V4 10 Later 17 Option Switch Settings 17 Expander Settings 17 Removing Detectors 18 Learning SmartKey 18 SmartKey 19 Learning Devices directly...

Страница 3: ...stalled SignalSecurity further enhances network reliability with each device already aware of the number of communication paths available to it The 8XP W 32XP W expanders can be used on any premier co...

Страница 4: ...88 168 640 to V4 X X Relearn if you Flash Elite 12 W 24 W 48 W to V4 X X V2 X X V3 X X All Versions Yes No No V4 X X 1 X X 2 X X Yes No No 3 0 6 No No No V3 Multiple Expander Support V2 introduced mul...

Страница 5: ...that they are registered on the receiver or control panel and that Mesh Networks and routing are established correctly Please refer to the relevant section in this document to Learn Devices to the sy...

Страница 6: ...Legacy Contact Technical Support for a Legacy Manual Ensure all Option Switches are off See Page 7 Learn Devices to Control Panel See Page 10 Onwards set attributes See Page 10 Onwards Place Devices...

Страница 7: ...tions Switch Use to select the receiver functionality depending on panel firmware Switch 1 ON firmware dependant please see the relevant programming section Switch 2 ON Legacy Mode OFF Ricochet Switch...

Страница 8: ...an be used for most installations However under certain conditions it may be necessary to use screened cable Selecting an Address Each expander must be assigned a different address using the DIL switc...

Страница 9: ...N A N A N A N A N A N A N A N A N A N A N A N A N A N A Premier Elite 168 Exp 1 Exp 2 Exp 1 Exp 2 N A N A N A N A N A N A N A N A N A N A N A N A Expander Address 1 5 1 5 N A N A N A N A N A N A N A N...

Страница 10: ...ed Ricochet learn menu accessible via the key when in Engineer menu This new feature is only for devices SmartKey should be learnt to the system in the User Menu as described later in this section Lea...

Страница 11: ...pe Area When learning devices if no editing has taken place of the control panel onboard hardwired zones these will be switched to Not Used after the first Ricochet device is learned to the system the...

Страница 12: ...se this key to exit the Learn Menu Premier EliteV2 00 V2 09 24 48 88 168 640 Ricochet V2 xx Option Switches All Off Introduction V2 xx firmware added the option to learn Ricochet devices through the Z...

Страница 13: ...is the default mode for all single technology motion detectors Hybrid Mode Hybrid mode is used to control the reporting functions for devices When in this mode devices are awake only when the system...

Страница 14: ...n Learning 20s Zone 00 Learn P R P 0 0 y Zone 00 P0 0 Not sed n n y Zone 00 Attrib y Zone 00 Attrib2 A Zone 00 Areas A y Zone 00 Text n n y Zone 00 Chime Silent n n y Zone 00 Test Remote Test Off n n...

Страница 15: ...on Whilst it is possible to learn at any point during the programming of the system learning and testing the functionality of the Premier Elite SmartKey after all devices have been placed will ensure...

Страница 16: ...A Please refer to page 27 for details of the LED AUX funtions To disable two stage arming please refer to INS176 8 or later and check Global Options System Config options 38 48 Once the 16 slots on a...

Страница 17: ...r s mode by entering the engineer code followed by then 2 Enter to select the Assign Radio Device menu if an error tone is generated then the receiver is not installed or configured correctly 3 Enter...

Страница 18: ...e receiver and work downwards The users available will vary depending on the control panel Control Panel Available Users Premier 412 Users 1 to 31 Premier 816 Users 1 to 31 Premier 832 Users 1 to 63 S...

Страница 19: ...he SmartKey from e g 4 Press the key the panel will generate an acceptance tone and the SmartKey is no longer assigned to the selected user Note If the SmartKey was assigned to user 02 onwards the use...

Страница 20: ...ter Engineer Utilities now includes a new Ricochet Diagnostics menu This menu displays information about the live system and is split into Premier Elite SmartKey and Ricochet devices via Zones and Use...

Страница 21: ...ion from the device was over an hour ago Zone 00 P R No msg recvd yet This display shows that no message has been received yet this would normally be seen on a recently powered up system wait 15 minut...

Страница 22: ...ed onto the system ser002 Ricochet Partarm Bat OK Shows the different messages displayed when the relevant buttons are pressed ser002 Ricochet Disarm Bat OK ser002 Ricochet ullarm Bat OK ser002 Ricoch...

Страница 23: ...Zone 00 Shock Status aaaSpdtt Zone 00 Shock P Zone 00 Shock P C Zone 00 Not Ricochet C B ser000 Ricochet Not Ricochet U ser002 Ricochet Not connected Zone 00 Shock C Zone 00 Shock hr since msg C C se...

Страница 24: ...nabled when the expander is in tamper When in commission mode the RF signal is attenuated by 6 dB and will reject weak signals This means that when devices are placed into their final locations and co...

Страница 25: ...being used to trigger 24 hour circuits or where the zone is required to chime ensure the device attributes are at the default Always Awake as detailed on page 26 The two additional inputs may also be...

Страница 26: ...W and Impaq Plus W For example a Impaq Contac W on a door which you need to know is opened regardless of system state or devices such as PA buttons smoke detectors which have been connected to the in...

Страница 27: ...xiliary devices from the control panel outputs The function keys should first be enabled either from the Engineers Keypad or Ricochet Monitor Once enabled the user can enter Auxiliary mode by pressing...

Страница 28: ...ee alarm status LED s will flash to indicate an arm failure In the case of users assigned to multiple areas the whole system should be unset and each area investigated to determine the cause of the ar...

Страница 29: ...g Voltage 10 13 7VDC Current Consumption 120mA Network 4 wire standard 7 0 2 alarm cable up to 250m Star Daisy Chain or any combination Outputs 1 8 Not Used Operating Temperature 10 C 14 F to 50 C 122...

Страница 30: ...II Hereby Texecom declares that the radio equipment type GCA1000 2 and GCD1000 2 Premier Elite 32XP W and Premier Elite 8XP W is in compliance with Directive 2014 53 EU The full EU declaration of conf...

Страница 31: ...Premier Elite 8XP W 32XP W Installation Manual INS467 8 31 Notes...

Страница 32: ...Lancashire BB4 4PW England Technical Support UK Customers Tel 08456 300 600 Calls charged at local rate from a BT landline Calls from other networks may vary International Customers Tel 44 1706 233875...

Отзывы: