Premier Elite 8XP-W & 32XP-W Installation Manual
18
INS467-8
Removing Detectors
If a detector is no longer required it must be unassigned from the system. To remove a detector from a zone,
proceed as follows:
1.
Select engineer’s mode by entering the engineer code followed by
/
then
.
2.
Enter
to select the
All Zone Options
menu.
3.
Enter the two digit zone number that you want to remove the detector from e.g.,
.
4.
Enter
to program the zone type as
Null
. The panel will generate an acceptance tone and
the detector is no longer assigned to the selected zone.
Learning
SmartKey™
All
SmartKey™
must be assigned to one of the available users on the system.
SmartKey™
will always be
learned to the last available slot on the receiver and work downwards. The users available will vary depending
on the control panel:
Control Panel
Available Users
Premier 412
Users 1 to 31
Premier 816
Users 1 to 31
Premier 832
Users 1 to 63
SmartKey™
are assigned to users as follows:
1.
Select engineer’s mode by entering the engineer code followed by
/
then
.
2.
Enter
to select the
Program Users
menu.
3.
Enter the two digit user number that you want to assign the
SmartKey™
to e.g.,
.
4.
Press the
/
key, if an error tone is generated then the receiver is not installed or configured
correctly (see Receiver Installation above).
Programming Menu
Enter Code > ??
Program ser ??
Enter ser No.??
Enter User
Number
??
Program ser ??
Code : ******
Enter Engineers code
Then press
then
????
Acceptance Tone
from Panel
Program ser ??
Activate Devic20
Programming Menu
Enter Code > ??
All Zone Options
Enter Zone No.??
Enter Zone
Number
??
Zone ?? Type
??????
Enter Engineers code
Then press
then
????
Acceptance Tone
from Panel