Premier Elite 8XP-W & 32XP-W Installation Manual
INS467-8
19
5.
Press the power button
on the
SmartKey™
, the panel will generate an acceptance tone and the
SmartKey™
is now assigned to the selected user.
6.
If required, a user access code can also be assigned to user in the normal way.
SmartKey
™
If a
SmartKey™
is no longer required it must be unassigned from the system. To remove a
SmartKey
™
from a
user, proceed as follows:
1.
Select engineer’s mode by entering the engineer code followed by
/
then
.
2.
Enter
to select the
Program Users
menu.
3.
Enter the two digit user number that you want to remove the
SmartKey™
from e.g.,
.
4.
Press the
/
key, the panel will generate an acceptance tone and the
SmartKey™
is no longer
assigned to the selected user.
Note:
If the
SmartKey™
was assigned to user 02 onwards the user
access code is also deleted.
Learning Devices directly to the 8XP-W & 32XP-W
Learning devices directly to the receiver is only applicable to legacy systems..
For all Legacy Control panels, please contact Technical Support to obtain a legacy manual.
Using the Engineers Keypad
The Engineers Keypad functionality is only applicable to legacy systems..
For all Legacy Control panels, please contact Technical Support to obtain a legacy manual.
Programming Menu
Enter Code > ??
Program ser ??
Enter ser No.??
Enter User
Number
??
Program ser ??
Code : ******
Enter Engineers code
Then press
then
????
Acceptance Tone
from Panel