TROUBLESHOOTING
WARNING
Turn off the engine and pull out the ignition cable before
making any inspection or adjustments.
If after making an adjustment or repair to the engine, and
you let it run for a few minutes, remember that the
exhaust and other parts will get hot.
Do not touch these parts as these may burn you.
Fault
Possible causes
Remedy
The unit does not operate
smoothly and vibrates
intensively
Bolts loose
Auger unit mounting loose
Check bolts
Check auger unit mounting
Engine does not run
Throttle lever in wrong
position
Spark plug defective
Fuel tank empty
Fuel cock closed
Check setting
Replace spark plug
Top up fuel
Open fuel cock
Engine does not run smoothly
Bad Fuel
Spark plug dirty
Empty Fuel Tank and refill with
Fresh Fuel
Clean the spark plug
Drive power falls
Clutch play too large
Drive Belt loose or
damaged
Adjust clutch cable
Replace Drive Belt
Contact authorized customer
service
The engine will not start or dies
after a short period of time
Choke in wrong position
Spark plug Fouled
No fuel
Check Choke setting
Clean or replace spark plug
(electrode spacing 0.6mm)
Top up fuel
Inadequate or no ejection
Snow ejection until
blocked
Plow screw not turning
Shearing bolts sheared
Clean the snow ejection unit with a
solid object
Adjust Auger clutch cable
Replace shear bolts or contact
authorized customer service
The snow is not removed fully
Skids maladjusted
Adjust the skids