Power Requirements
3-16
Details
3.4.5
Power Requirements
The TPA032D02 class-D stereo audio power amplifier evaluation module is
designed to operate from a supply voltage between 9 V and 14 V. For best
performance (highest output power with lowest distortion), the module should
be operated at 12 V.
The TI plug-n-play audio amplifier evaluation platform provides several
options for powering the TPA032D02 class-D EVM. Table 3–3 shows the
platform jumper and switch settings for each power source option (see the
User’s Guide for the TI plug-n-play audio amplifier platform, TI Literature
Number SLOU011 for more information). The TPA032D02 class-D EVM
requires no setup for power source selection.
Table 3–3. Platform Jumper and Switch Settings for the TPA032D02 EVM Power Inputs
POWER TYPE (Note 2)
JP1
JP2
JP3
JP4
JP5
JP6
JP7
JP8
S1
S2
S3
VCC (J1)
ON
OFF
OFF
ON
ON
Mute
X
Hi
ON
Note 3
U5
AC/DC (J2)
OFF
ON
OFF
ON
ON
Mute
X
Hi
ON
Note 3
U5
Notes:
1) ON = Jumper installed, OFF = Jumper NOT Installed, X = Don’t care
2) Install a voltage regulator EVM (SLVP097) in platform socket U6 for VDD power to EVM control inputs.
3) Set to ON when Tone Control Board SLOP109 is installed in U1, otherwise set to OFF..
Although the TPA032D02 amplifier IC draws approximately 1.6 A per channel
from the power supply during continuous full power output, peak current draw
can be as high as 2.3 A per channel. Any power supply connected to the
platform should be capable of providing 4.6 A (peak) to avoid clipping of the
output signal during voltage peaks. Current consumption driving speakers at
normal listening levels is typically 0.1 A or less.
A V
DD
supply of 5 V is required for normal operation of the TPA032D02 EVM.
V
DD
can either be applied to the platform V
DD
power input terminals (J6) or a
voltage regulator (SLVP097 or equiv.) can be installed in platform socket U6
to provide V
DD
from the platform V
CC
supply.
The platform is equipped with overvoltage and reverse-polarity supply voltage
input protection in the form of fused crowbar circuits.
-
V
DD
voltage applied to platform screw terminals J6 MUST NOT exceed
the absolute maximum rating for the TPA032D02 amplifier IC installed on
the evaluation module (5.5 V) or damage to the IC may result. In no case
should V
DD
voltage of the incorrect polarity or in excess of 6.0 V be applied
to screw terminals J6 of the platform, or the power protection circuit on the
V
DD
line will trip.
-
V
CC
voltage applied to the platform MUST NOT exceed the maximum
voltage input specified for the voltage regulator module installed in socket
U6 (12 V for the SLVP097), or damage to the voltage regulator module
may result. In no case should V
CC
voltage applied to the platform exceed
15 V, or the overvoltage protection circuit on the V
CC
bus will trip.