NOTE
If ADEVT, N2HET1, or GIOB is used as a trigger source, the connection to the MibADC1
module trigger input is made from the output side of the input buffer. This way, a trigger
condition can be generated either by configuring the function as output onto the pad (through
the mux control), or by driving the function from an external trigger source as input. If the
mux control module is used to select different functionality instead of the ADEVT, N2HET1[x]
or GIOB[x] signals, then care must be taken to disable these signals from triggering
conversions; there is no multiplexing on the input connections.
If ePWM_B, ePWM_A2, ePWM_AB, N2HET2[1], N2HET2[5], N2HET2[13], N2HET1[11],
N2HET1[17], or N2HET1[19] is used to trigger the ADC, the connection to the ADC is made
directly from the N2HET or ePWM module outputs. As a result, the ADC can be triggered
without having to enable the signal from being output on a device terminal.
NOTE
For the RTI compare 0 interrupt source, the connection is made directly from the output of
the RTI module. That is, the interrupt condition can be used as a trigger source even if the
actual interrupt is not signaled to the CPU.
7.5.2.2
MibADC2 Event Trigger Hookup
Table 7-21
lists the event sources that can trigger the conversions for the MibADC2 groups.