SPRS293A − OCTOBER 2005 − REVISED NOVEMBER 2005
61
POST OFFICE BOX 1443
•
HOUSTON, TEXAS 77251−1443
absolute maximum ratings over operating case temperature range (unless otherwise noted)
†
Supply voltage range, CV
DD
(see Note 2):
− 0.3 V to 1.8 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Supply voltage range, DV
DD
(see Note 2)
−0.3 V to 4 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage ranges:
−0.3 V to DV
DD
+ 0.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage ranges:
−0.3 V to DV
DD
+ 0.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating case temperature range, T
C
0
_
C to 90
_
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65
_
C to 150
_
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 2: All voltage values are with respect to VSS
.
recommended operating conditions
MIN
NOM
MAX
UNIT
CVDD
Supply voltage, Core‡
1.14§
1.20§
1.32
V
DVDD
Supply voltage, I/O‡
3.13
3.3
3.47
V
VSS
Supply ground
0
0
0
V
VIH
High-level input voltage
All signals except CLKS1, DR1, and RESET
2
V
VIH
High-level input voltage
CLKS1, DR1, and RESET
2
V
VIL
Low-level input voltage
All signals except CLKS1, DR1, and RESET
0.8
V
VIL
Low-level input voltage
CLKS1, DR1, and RESET
0.3*DVDD
V
IOH
High-level output current¶
All signals except ECLKOUT, CLKOUT2, CLKS1, and
DR1
–8
mA
IOH
High-level output current¶
ECLKOUT and CLKOUT2
–16
mA
IOL
Low-level output current¶
All signals except ECLKOUT, CLKOUT2, CLKS1, and
DR1
8
mA
IOL
Low-level output current¶
ECLKOUT and CLKOUT2
16
mA
CLKS1 and DR1
3
mA
VOS
Maximum voltage during overshoot (See Figure 18)
4#
V
VUS
Maximum voltage during undershoot (See Figure 19)
−0.7#
V
TC
Operating case temperature
0
90
_
C
‡ For this device, the core supply should be powered up prior to (and powered down after), the I/O supply. Systems should be designed to ensure
that neither supply is powered up for an extended period of time if the other supply is below the proper operating voltage.
§ These values are compatible with existing 1.26V designs.
¶ Refers to DC (or steady state) currents only, actual switching currents are higher. For more details, see the device-specific IBIS models.
# The absolute maximum ratings should not be exceeded for more than 30% of the cycle period.