2 Quick Start
The quick start shows a minimalist startup process to get the GUI working with the EVM and to see a simple
example for data collection. Details on each step are found elsewhere within the user's guide. Specifics
regarding the GUI installation steps are found in
2.1 Step 1 - Hardware Setup
The EVM hardware configuration consists of verifying the supply settings and adding a source voltage to be
converted.
1. Verify that the TLA2024 supply voltage is set to the 5-V setting at JP1.
2. Connect an input voltage to AIN0. The PAMBoard supply voltage can be used as a voltage source to the
TLA2024. Use the 3.3-V source found at header J1 pin 1 and with a wire jumper connect to the J6 header at
pin 1 (A0).
Figure 2-1. Hardware Setup
2.2 Step 2 - USB Connection and GUI Startup
The TLA2024EVM GUI software can be run from a browser window. Additional software may need to be
installed if not installed previously. See
for additional details. Once the GUI has started, plug the
TLA2024VM-PDK into an available USB port on the PC.
Quick Start
SBAU368 – FEBRUARY 2021
TLA2024EVM-PDK User's Guide
5
Copyright © 2021 Texas Instruments Incorporated