5.2.3.1.2 Write Register Options
The GUI default option for register writes is
Immediate Write
. When
Immediate Write
is selected, any register
configuration changes are immediately written from the GUI to the TLA2024 device. Using the
Immediate Write
option ensures that what is being displayed is what is configured in the TLA2024.
If the write register drop-down menu selection is for a
Deferred Write
, then the write register buttons
WRITE
REGISTER
and
WRITE ALL REGISTERS
become enabled. Similar to the functionality of the read register
buttons, the
WRITE REGISTER
button will write the configuration for the currently selected register. When
selecting the
WRITE ALL REGISTERS
button all configurable registers will be written.
Figure 5-25. Register Write Options
TLA2024EVM-PDK GUI
SBAU368 – FEBRUARY 2021
TLA2024EVM-PDK User's Guide