5.2.2.5 Capture Configuration Settings
A slide-out menu is viewable on the right side of the
Chart
window. By clicking the slide-out for
Show Capture
Settings
various configurations display and are selectable. The drop-down menu
Capture Settings
are:
•
Select data rate
for the data output conversion rate
•
Select MUX channels
by choosing the desired input channels to be converted
•
Select FSR
for choosing the voltage input measurement range
Figure 5-20. Capture Settings
5.2.3 Configuration
The
Register Map
window contains information about the configuration and the last conversion data from the
TLA2024 device. The
Conversion
register contains the value of the last 12-bit conversion result read from the
TLA2024. The conversion data are 12-bit left-justified in the 16-bit register.
As the TLA2024 is a programmable device, the
Config
register is the only programmable register and is 16 bits
in length.
A number of control buttons and drop-down menus exist to configure the
Register Map
read and write operations
when data are written and read from the TLA2024.
Throughout the
Register Map
window question mark icons appear. Clicking on these icons open details
pertaining to the items in the locations where they appear.
TLA2024EVM-PDK GUI
SBAU368 – FEBRUARY 2021
TLA2024EVM-PDK User's Guide
27
Copyright © 2021 Texas Instruments Incorporated