MSP430F42x
MIXED SIGNAL MICROCONTROLLER
SLAS421A − APRIL 2004 − REVISED JUNE 2007
18
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted)
supply current into AV
CC
+ DV
CC
excluding external current (see Note 1)
PARAMETER
TEST CONDITIONS
MIN
NOM
MAX
UNIT
I
(AM)
Active mode,
f
(MCLK)
= f
(SMCLK)
= f
(DCO)
= 1 MHz,
f
(ACLK)
= 32,768 Hz, XTS_FLL = 0
(program executes in flash)
T
A
= −40
°
C to 85
°
C
V
CC
= 3 V
400
500
μ
A
I
(LPM0)
Low-power mode, (LPM0/LPM1)
f
(MCLK)
= f
(SMCLK)
= f
(DCO)
= 1 MHz,
f
(ACLK)
= 32,768 Hz, XTS_FLL = 0
FN_8=FN_4=FN_3=FN_2=0 (see Note 2)
T
A
= −40
°
C to 85
°
C
V
CC
= 3 V
130
150
μ
A
I
(LPM2)
Low-power mode, (LPM2) (see Note 2)
T
A
= −40
°
C to 85
°
C
V
CC
= 3 V
10
22
μ
A
T
A
= −40
°
C
1.5
2.0
I
Low power mode (LPM3) (see Note 2)
T
A
= 25
°
C
V
3 V
1.6
2.1
A
I
(LPM3)
Low-power mode, (LPM3) (see Note 2)
T
A
= 60
°
C
V
CC
= 3 V
1.7
2.2
μ
A
T
A
= 85
°
C
2.0
2.6
T
A
= −40
°
C
0.1
0.5
I
(LPM4)
Low-power mode, (LPM4) (see Note 2)
T
A
= 25
°
C
V
CC
= 3 V
0.1
0.5
μ
A
I
(LPM4)
Low power mode, (LPM4) (see Note 2)
T
A
= 85
°
C
V
CC
3 V
0.8
2.5
μ
A
NOTES:
1. All inputs are tied to 0 V or V
CC
. Outputs do not source or sink any current.
The current consumption in LPM2, LPM3, and LPM4 are measured with active Basic Timer1 and LCD (ACLK selected).
The current consumption of the SD16 and the SVS module are specified in their respective sections.
LPMx currents measured with WDT disabled.
The currents are characterized with a KDS Daishinku DT−38 (6 pF) crystal.
2. Current for brownout included.
current consumption of active mode versus system frequency
I
(AM)
= I
(AM) [1 MHz]
×
f
(System) [MHz]
current consumption of active mode versus supply voltage
I
(AM)
= I
(AM) [3 V]
+ 170
μ
A/V
×
(V
CC